◆ Open access emergency medicine : OAEM2026-01-01

Correlation Between Hemodynamic Parameters Measured by Ultrasonic Cardiac Output Monitor and Serum Troponin I Levels in Pediatric Septic Shock Patients: A Prospective Observational Study.

Indra Sandinirwan, Dzulfikar Djalil Lukmanul Hakim, Sri Endah Rahayuningsih, Saptadi Yuliarto, Stanza Uga Peryoga

一句话结论 · In one sentence

Serum cTnI levels increased during the first 24 hours of pediatric septic shock and were associated with dynamic hemodynamic changes. These findings suggest a potential role for integrating serial troponin measurement with non-invasive hemodynamic monitoring. Further studies with larger cohorts are needed to validate these observations.

原始摘要(英文原文)· Original abstract
PURPOSE: Pediatric septic shock is frequently associated with myocardial dysfunction and high mortality. Cardiac troponin I (cTnI) is a biomarker of myocardial injury, while the Ultrasonic Cardiac Output Monitor (USCOM) enables non-invasive hemodynamic assessment. This study aimed to explore the correlation between USCOM-derived hemodynamic parameters and serum cTnI levels in pediatric septic shock, and to examine the association of inotropic therapy with troponin levels. PATIENTS AND METHODS: A prospective observational study was conducted in 32 pediatric patients with septic shock admitted to Hasan Sadikin Hospital, Bandung, between May and September 2025. Serial USCOM measurements were performed at 1, 3, 6, 12, and 24 hours to assess cardiac index (CI), stroke volume index (SVI), Smith-Madigan Inotropy Index (SMII), and systemic vascular resistance index (SVRI). Serum cTnI levels were measured at 6 and 24 hours using a high-sensitivity assay. Correlations were analyzed using Spearman's test, and multivariable regression was applied to explore independent associations. RESULTS: Median cTnI levels increased significantly from 71 pg/mL at 6 hours to 201 pg/mL at 24 hours (p < 0.01). Early changes in SVI (1-6 hours) were negatively correlated with cTnI at 6 hours (r = -0.409; p = 0.020). SMII at 1 hour was positively correlated with cTnI at 24 hours (r = 0.409; p = 0.025), while SVI at 24 hours showed a positive correlation with cTnI at 24 hours (r = 0.387; p = 0.035). The number of inotropic agents was independently associated with higher cTnI levels at both 6 and 24 hours. CONCLUSION: Serum cTnI levels increased during the first 24 hours of pediatric septic shock and were associated with dynamic hemodynamic changes. These findings suggest a potential role for integrating serial troponin measurement with non-invasive hemodynamic monitoring. Further studies with larger cohorts are needed to validate these observations.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

Correlation Between Hemodynamic Parameters Measured by Ultrasonic Cardiac Output Monitor and Serum Troponin I Levels in Pediatric Septic Shock Patients: A Prospective Observational Study. — 科研速览 Science Skim