Outcomes Related to the Use of Standard-Standard versus Standard-Offset Magnetically Controlled Growing Rods.
Simon Blanchard, Thomas A Coleman, Jacob Jordan, Lorena Floccari, Joshua Pahys, Sulagna Sarkar, John W Stelzer, Paul Sponseller,
Orthopedics Center, Children's Hospital of Philadelphia, Philadelphia, PA. · Department of Orthopedic Surgery, Akron Children's Hospital, Akron, OH.
Key points
From the paper's conclusion- The lengthening achieved and complication risks are similar across rod orientations at 2 and 5 years. At 2 years post-index surgery, surgeons appear to be attempting to lengthen patients who receive standard-offset rods to a greater extent without any additional clinical benefit. Further investigation is needed to further elucidate the best practices of MCGR utilization and to determine which patients would benefit from one orientation compared with the other.
Abstract
BACKGROUND: Magnetically controlled growing rods (MCGRs) are used to perform growth-friendly spinal deformity correction. A key variable that remains debated in determining the optimal use of MCGRs is the orientation of the rods: parallel to one another (standard-standard) versus antiparallel (standard-offset). This study aims to determine if the orientation of the rods has an impact on lengthening outcomes and complication rates. METHODS: A retrospective analysis of an international multicenter prospective registry of early-onset scoliosis patients was conducted. Inclusion criteria were patients who underwent bilateral MCGR index surgery with available lengthening data for a minimum of 2 years. Lengthening analyses were discontinued following revision or exchange of the implants. Accumulated programmed and actual lengthening was recorded at the first visit, 2-year, and 5-year intervals following index surgery. RESULTS: Six hundred sixty-eight patients met the inclusion criteria for the study, including 327 females (49%) and 341 males (51%) patients who were 8.0±1.9 years old at index surgery, with a mean major coronal curve of 74 degrees (18 to 134 degrees). Three hundred twenty-three (48%) patients received standard-standard and 345 (52%) patients received standard-offset MCGRs. Patients with standard-standard rods experienced complications at a similar rate to patients who received standard-offset rods [n=137 (42%) vs. n=128 (37%); P=0.161]. In terms of achieved lengthening, no differences were found across actuator orientations at the first lengthening, or in the achieved lengthening accumulated by patients who were still undergoing lengthening procedures at 2 or 5 years post-implantation. CONCLUSIONS: The lengthening achieved and complication risks are similar across rod orientations at 2 and 5 years. At 2 years post-index surgery, surgeons appear to be attempting to lengthen patients who receive standard-offset rods to a greater extent without any additional clinical benefit. Further investigation is needed to further elucidate the best practices of MCGR utilization and to determine which patients would benefit from one orientation compared with the other. LEVEL OF EVIDENCE: Level 3.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Longitudinal Radiographic Outcomes and Revision Burden After Magnetically Controlled Growing Rod Treatment for Early-Onset Scoliosis.Journal of clinical medicine · 2026
- Surgical treatment of early-onset scoliosis: traditional active apex correction (APC) versus a hybrid construct combining convex apical control and a concave magnetically controlled growing rod (MCGR): a retrospective comparative cohort study.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2026
- [Translated article] Effectiveness and safety of vertebral distraction techniques in early-onset scoliosis: a systematic review and meta-analysis.Revista espanola de cirugia ortopedica y traumatologia · 2026
- Long-Term Outcomes of the Sliding-Growing Rod Technique in Early-Onset Scoliosis: Deformity Control, Spinal Growth, and Implant Survival.Global spine journal · 2026
- Deep Implant-Associated Infection in Magnetically Controlled Versus Traditional Growing Rods for Early-Onset Scoliosis: A Narrative Review of Clinical Evidence and Bioengineering ConsiderationsBioengineering · 2026
- Five-year outcomes of the one-way self-expanding rod for early-onset scoliosis: a prospective clinical trial.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026