Anomaly Detection With an Expanded Standardized First-Trimester Fetal Anatomic Ultrasound Screening Protocol.
Peixin Chen, Yue Jie, Zhenhua Wang, Guoqing Du, Lanting Huang, Ruolan Xie, Shen Zhang, Hui Chen,
Department of Ultrasound, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, Guangdong Province, China.
Key points
From the paper's conclusion- Compared with current ISUOG first-trimester screening protocols, StaFFAUS demonstrated superior anomaly detection and diagnostic performance. As an expanded standardized screening framework incorporating additional first-trimester anatomic views, it improves early detection of fetal structural abnormalities while remaining clinically feasible.
Abstract
OBJECTIVE: To evaluate the clinical utility of a novel comprehensive StaFFAUS (standardized first-trimester fetal anatomic ultrasound screening) protocol. METHODS: This retrospective single-center study included pregnant patients undergoing first-trimester ultrasound screening at 11 6/7-13 6/7 weeks of gestation between 2013 and 2024. Identification of gold-standard-confirmed anomalies was assessed retrospectively according to an expanded first-trimester screening protocol with 30 imaging planes called StaFFAUS, the International Society of Ultrasound in Obstetrics and Gynecology (ISUOG) Minimum-Requirement, and the ISUOG Detailed protocols. Diagnostic performance was evaluated in a subset validation cohort made up of all fetuses with structural abnormalities and a control group without structural abnormalities, selected at a 1:3 ratio. Examination time was assessed in 100 randomly selected scans. Pairwise DeLong comparisons were used to compare the area under the receiver operating characteristic curve (AUROC) between groups. RESULTS: A total of 18,250 women carrying 19,417 fetuses were considered for inclusion. First-trimester screening identified 246 fetuses with structural abnormalities, comprising 580 individual detected anomalies (3.0%). Using 694 gold-standard-confirmed anomalies as the reference standard, StaFFAUS achieved a significantly higher anomaly-level detection rate than the ISUOG Detailed protocol (83.6% vs 67.3%, P<.001) and the ISUOG Minimum-Requirement protocol (83.6% vs 47.7%, P<.001). In the diagnostic performance cohort of 326 fetuses with anomalies and 978 fetuses in a matched control group (N=1,304), StaFFAUS showed the highest sensitivity (75.5%), accuracy (90.8%), and AUROC (0.857, 95% CI, 0.830-0.884), whereas the ISUOG Minimum-Requirement protocol achieved the highest specificity (99.0%). The AUROC of StaFFAUS was significantly higher than those of both the ISUOG Detailed (AUROC 0.820, P<.001) and ISUOG Minimum-Requirement (AUROC 0.769, P<.001) protocols. Median examination time was 28 minutes (interquartile range 22-35.5 minutes). CONCLUSION: Compared with current ISUOG first-trimester screening protocols, StaFFAUS demonstrated superior anomaly detection and diagnostic performance. As an expanded standardized screening framework incorporating additional first-trimester anatomic views, it improves early detection of fetal structural abnormalities while remaining clinically feasible.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Impact of first-trimester ultrasound on early detection of major fetal anomalies: Nationwide population-based study of over 1 million pregnanciesPLoS Medicine · 2025
- Early Detection of Major Fetal Structural Anomalies in the First Trimester: A Retrospective Single-Center Study in an Unselected Population.Journal of clinical medicine · 2026
- Structural Fetal Anomalies Identified During First-Trimester Screening: A Single-Centre Experience in Romania.Medicina (Kaunas, Lithuania) · 2026
- An optimized integrated ultrasound-cardiac magnetic resonance imaging strategy for accurate prenatal diagnosis of fetal aortic arch branch abnormalities: a prospective dual-center study.Quantitative imaging in medicine and surgery · 2026
- Development of an Integrated Deep Learning Approach for Detecting Fetal Brain Abnormalities at Routine Second Trimester US Scan: A Multicenter StudyRadiology Artificial Intelligence · 2026
- Artificial intelligence model based on the detection of key anatomical structures for identifying standard planes on ultrasound of the first-trimester fetal central nervous system: a multicenter study.Quantitative imaging in medicine and surgery · 2026