Use of Artificial Intelligence–Based Software to Aid in the Identification of Ultrasound Findings Associated With Fetal Congenital Heart Defects
Jennifer Lam‐Rachlin, Rajesh Punn, Sarina K. Behera, Miwa Geiger, Matthias Lachaud, Nadine David, Sara Garmel, Nathan S. Fox,
Centre Hospitalier Universitaire de Grenoble · Wayne State University
Key points
From the paper's conclusion- To evaluate whether artificial intelligence (AI)-based software was associated with enhanced identification of eight second-trimester fetal ultrasound findings suspicious for congenital heart defects (CHDs) among obstetrician-gynecologists (ob-gyns) and maternal-fetal medicine specialists.
Abstract
OBJECTIVE: To evaluate whether artificial intelligence (AI)-based software was associated with enhanced identification of eight second-trimester fetal ultrasound findings suspicious for congenital heart defects (CHDs) among obstetrician-gynecologists (ob-gyns) and maternal-fetal medicine specialists. METHODS: A dataset of 200 fetal ultrasound examinations from 11 centers, including 100 with at least one suspicious finding, was retrospectively constituted (singleton pregnancy, 18-24 weeks of gestation, patients aged 18 years or older). Only examinations containing two-dimensional grayscale cines with interpretable four-chamber, left ventricular outflow tract, and right ventricular outflow tract standard views were included. Seven ob-gyns and seven maternal-fetal medicine specialists reviewed each examination in randomized order both with and without AI assistance and assessed the presence or absence of each finding suspicious for CHD with confidence scores. Outcomes included readers' performance in identifying the presence of any finding and each finding at the examination level, as measured by the area under the receiver operating characteristic curve (AUROC), sensitivity, and specificity. In addition, reading time and confidence were evaluated. RESULTS: The detection of any suspicious finding significantly improved for AI-aided compared with unaided readers with a significantly higher AUROC (0.974 [95% CI, 0.957-0.990] vs 0.825 [95% CI, 0.741-0.908], P =.002), sensitivity (0.935 [95% CI, 0.892-0.978] vs 0.782 [95% CI, 0.686-0.878]), and specificity (0.970 [95% CI, 0.949-0.991] vs 0.759 [95% CI, 0.630-0.887]). AI assistance also resulted in a significant decrease in clinician interpretation time and increase in clinician confidence score (226 seconds [95% CI, 218-234] vs 274 seconds [95% CI, 265-283], P <.001; 4.63 [95% CI, 4.60-4.66] vs 3.90 [95% CI, 3.85-3.95], P <.001, respectively). CONCLUSION: The use of AI-based software to assist clinicians was associated with enhanced identification of findings suspicious for CHD on prenatal ultrasonography.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- AI assistance for fetal ultrasound interpretation in a multi-reader study.NPJ digital medicine · 2026
- AI-Enabled Digital Stethoscope for Early Detection of Congenital Heart Disease: Prospective Study.Pediatric cardiology · 2026
- AI-Driven Three-Dimensional Reconstruction of Fetal Cardiovascular Pathways from Ultrasound Sweep Videos for Congenital Heart Disease Screening.Bioengineering (Basel, Switzerland) · 2026
- Combining AI-enabled acquisition and interpretation for screening aortic stenosis: a prospective validation and pragmatic workflowEuropean Heart Journal · 2026
- Diagnostic Accuracy of Artificial Intelligence-Enabled Cardiac Auscultation for Detecting Clinically Significant Valvular Heart Disease: A Systematic Review and Meta-Analysis.Cardiology in review · 2026
- Real-world performance of AI-guided focused cardiac ultrasound: feasibility, interpretability, and detection of significant heart diseaseEuropean Heart Journal · 2026