P008. Within-Patient Analysis of CPAP/APAP Treatment Trajectories in OSA

L Chen, N Malagutti, S Miller

Observational · n=121

Key points

From the paper's conclusion
  • Patients were additionally classified into longitudinal PAP trajectories: (1) APAP-to-CPAP transition with continued CPAP use, (2) CPAP-to-APAP transition with continued APAP use, and (3) repeated switching between CPAP and APAP.

Abstract

Background Despite widespread use of fixed-pressure CPAP and APAP for treating OSA, clinicians’ uncertainty remains regarding which patients are best suited to each treatment modality. Longitudinal empirical studies examining real-world transitions between PAP modes remain limited. We explored longitudinal PAP treatment trajectories using a novel within-patient analytical framework. Methods We performed a retrospective longitudinal paired analysis of 121 patients who used both CPAP and APAP during follow-ups. Within-patient comparisons minimised inter-patient variability. Residual AHI, adherence, leak, pressure characteristics, follow-up burden, and care duration were analysed. Patients were additionally classified into longitudinal PAP trajectories: (1) APAP-to-CPAP transition with continued CPAP use, (2) CPAP-to-APAP transition with continued APAP use, and (3) repeated switching between CPAP and APAP. Results Within-patient analyses demonstrated that CPAP was more likely than APAP to achieve lower residual AHI. No significant adherence difference was observed between modes. CPAP was associated with higher leak values. Longitudinal trajectory analyses demonstrated significant differences between trajectory groups. Notably, Trajectory 3 patients demonstrated the least favorable overall treatment profile, with persistently higher residual AHI, higher leak values, and lower compliance, despite requiring the greatest number of follow-up visits and the longest care duration. Conclusions Longitudinal within-patient PAP trajectory modelling may provide a novel framework for understanding real-world treatment adaptation in OSA. Repeated PAP mode switching was associated with poorer treatment outcomes and greater healthcare utilisation, potentially identifying more complex treatment courses. Multi-centre studies are required to validate these findings and clarify contributing patient and clinical management factors.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

P008. Within-Patient Analysis of CPAP/APAP Treatment Trajectories in OSA — Science Skim