O015. WatchPAT® overdiagnoses obstructive sleep apnoea in children and adolescents
E McLeod, G Nixon, N Verginis, R Horne, M Davey, L Nisbet
Key points
From the paper's conclusion- We evaluated the validity and diagnostic accuracy of WP300 compared with simultaneous PSG for assessing OSA severity in children aged <12 and ≥12 years.
Abstract
Introduction Obstructive sleep apnoea (OSA) is a common paediatric condition associated with significant morbidity. Polysomnography (PSG), the gold-standard diagnostic modality, is limited by accessibility, cost and tolerance. The WatchPAT®300 (WP300, Itamar Medical), a device using peripheral arterial tonometry (PAT) to estimate sleep and respiratory events, is validated for OSA diagnosis in adults but shows inconsistent results in limited studies of children. We evaluated the validity and diagnostic accuracy of WP300 compared with simultaneous PSG for assessing OSA severity in children aged <12 and ≥12 years. Methods Prospective study of children aged 8-18 undergoing concurrent in-laboratory PSG with WP300. Exclusion criteria included medications affecting PAT signal, inadequate probe fit, or major medical comorbidity. PSG was manually scored using paediatric criteria and WP300 data analysed with proprietary software. The obstructive apnoea-hypopnoea index (OAHI) defined OSA (≥1 event/h) and moderate-severe OSA (≥5 events/h). Results 79 children had concurrent PSG and WP300 studies (median age (IQR) 11.9 (10.0-13.6), 44%F, 65% OSA, 25% moderate-severe OSA). WP300 overestimated OAHI compared to PSG in the whole cohort (median (IQR) 3.9 (2.1-7.3) vs. 1.9 (0.5-5.0) events/h), and in both age groups (p<0.01). For OAHI≥1 event/h, WP300 demonstrated low specificity, incorrectly diagnosing OSA in 86% of children without OSA on PSG. However, WP300 yielded no false negatives. Performance improved for OAHI≥5 events/h, with 75% specificity. Discussion WP300 overestimated OSA severity and demonstrated poor specificity for mild disease. While high sensitivity may help detect most cases of moderate-severe OSA, overall diagnostic utility is limited, highlighting the need for paediatric-specific algorithms.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- P137. Understanding the automated scoring of WatchPAT® respiratory events in childrenSLEEP advances · 2026
- A photoplethysmography-based home sleep apnea test compared with polysomnography in children 2 to 6 years of age.Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine · 2026
- O018. Red Cell Distribution Width in Paediatric OSA: Signal and LimitationsSLEEP advances · 2026
- P170. Home-based limited channel sleep monitoring for paediatric obstructive sleep apnoeaSLEEP advances · 2026
- P102. Diagnostic accuracy of under-mattress sensor for OSA in primary careSLEEP advances · 2026
- Positional Obstructive Sleep Apnoea and Discordance Between Symptom-Based Screening and Polysomnography in Children.Children (Basel, Switzerland) · 2026