Establishing national diagnostic reference levels for adult nuclear medicine single-photon emission computed tomography imaging in Bahrain.
Mohamed Khaled Bucheer, Wadha Alyami
Department of Radiological Sciences, College of Applied Medical Sciences, King Saud University, P.O. Box 10219, Riyadh 11433, Saudi Arabia.
Key points
From the paper's conclusion- Overall, Bahrain's proposed DRLs were lower than regional values reported in Kuwait and Saudi Arabia and were comparable to European benchmarks.
Abstract
This study established diagnostic reference levels (DRLs) for common adult single-photon emission computed tomography (SPECT) procedures in Bahrain to support dose optimization and alignment with international radiation protection standards. Data were retrospectively collected from two major nuclear medicine centers, representing most national SPECT services. Administered radiopharmaceutical activities (MBq) for adult patients (70 kg ± 20%) undergoing routine examinations were analyzed. DRLs were calculated as the 75th percentile of administered activity following International Commission on Radiological Protection (ICRP) Publication 135. A total of 1098 studies were included. Variations between centers reflected differences in administration practices. Overall, Bahrain's proposed DRLs were lower than regional values reported in Kuwait and Saudi Arabia and were comparable to European benchmarks. The findings provide a national reference framework for optimization of nuclear medicine practice and support ongoing monitoring to maintain compliance with international radiation safety recommendations from the ICRP and International Atomic Energy Agency.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Local Diagnostic Reference Levels for Adult Bone SPECT/CT Imaging: A Multicenter Study in South AfricaWorld Journal of Nuclear Medicine · 2026
- Radiation Dose Assessment in Routine Adult Computed Tomography Examinations: A Multi-center Retrospective Study.Health physics · 2026
- Swiss survey and national diagnostic reference levels for PET/CT examinations in adults.Zeitschrift fur medizinische Physik · 2026
- Establishment of preliminary diagnostic reference levels for 18F-FDG PET/CT in adult lymphoma in Costa Rica.Radiation protection dosimetry · 2026
- The Current Status of Nuclear Medicine in AfricaJournal of Nuclear Medicine · 2025
- Adult diagnostic reference levels in computed tomography: A systematic review and analysis of regional variability.European journal of radiology · 2026