Radiation protection dosimetry

Assessment of weight-based variations in effective dose for common PET/CT scans in a tertiary hospital.

Abdallah T Al Said, Azhar A Rahman, Laith K Albadarneh, Ammar A Oglat, Fatin N Binti A Halim, Wesal Firas, Yahia Alshloul, Khaldoon M Radaideh

School of Physics, Universiti Sains Malaysia, 11800 USM Minden, Penang, Malaysia. · Department of Medical Radiologic Technologies, Faculty of Applied Medical Sciences, Al Al-Bayt University, Mafraq, Jordan.

Observational

Key points

From the paper's conclusion
  • Patient weight significantly influences the total effective dose in PET/CT examinations. These findings highlight the importance of considering patient-specific factors when evaluating radiation dose in clinical practice.

Abstract

BACKGROUND: Positron Emission Tomography/Computed Tomography (PET/CT) is a crucial imaging modality widely used for diagnosing and staging various cancers. Although patient weight is known to influence radiation dose, there is limited research on optimizing PET/CT protocols based on weight categories to minimize unnecessary exposure. OBJECTIVES: This study evaluates the effective dose for common PET/CT scans at Penang Hospital, with a particular focus on the influence of patient weight on both PET and CT dose components. Additionally, the study assesses whether weight-based dose protocols can contribute to dose optimization. METHODS: This retrospective study analyzed 1439 PET/CT scans performed at Penang Hospital. The effective dose was calculated using International Commission on Radiological Protection (ICRP) 103, 106, and 128 dose coefficients. Conversion factors used were 0.019 mSv/MBq for 18F-FDG, 0.0199 mSv/MBq for 68Ga-PSMA, and 0.021 mSv/MBq for 68Ga-DOTATATE. The CT dose component was estimated using the dose-length product (DLP) with an empirical conversion factor (k = 0.015 mSv·mGy-1·cm-1) for whole-body CT. RESULTS: The total effective dose for 18F-FDG (head-to-thigh and head-to-feet) scans was 12.34 and 16.38 mSv, respectively. For 68Ga-PSMA and 68Ga-DOTATATE scans, the total effective dose was 11.55 and 12.00 mSv, respectively. A statistically significant increase in dose was observed in heavier patients due to increased administered activity and CT parameters (P < .05). Weight had a smaller impact on PET dose in 68Ga-PSMA and 68Ga-DOTATATE compared to 18F-FDG. CONCLUSION: Patient weight significantly influences the total effective dose in PET/CT examinations. These findings highlight the importance of considering patient-specific factors when evaluating radiation dose in clinical practice.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Assessment of weight-based variations in effective dose for common PET/CT scans in a tertiary hospital — Science Skim