Regenerative biomaterials

The application of absorbable interference screws in anterior cruciate ligament reconstruction of the knee joint.

Junfeng Li, Jingying Dai, Zhixiong Lin, He Yang, Daimei Li, Xiaoyan Chen, Xinfeng Wang, Jingru Du,

State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, Hubei Key Discipline Laboratory of Orthopedic Tissue Injury and Repair, Wuhan University of Technology, Wuhan 430070, China. · Department of Orthopaedics, The Third Hospital of Zhangzhou, Zhangzhou 363003, China.

Key points

From the paper's conclusion
  • Collectively, these findings support the potential of the β-TCP/PLGA interference screw as a bioabsorbable fixation device for ACL reconstruction, combining mechanical stability with progressive degradation and bone integration.

Abstract

Anterior cruciate ligament (ACL) injury is a common sports-related condition that can result in knee instability, pain, functional impairment and subsequent osteoarthritis. ACL reconstruction relies on reliable graft fixation, for which conventional metallic and bioabsorbable interference screws have limitations in biocompatibility, degradation behavior or mechanical performance. Here, we developed a bioabsorbable interference screw composed of 30% β-tricalcium phosphate (β-TCP) and 70% poly(lactic-co-glycolic acid) (PLGA) for ACL reconstruction. The mechanical properties, in vitro degradation, biocompatibility and bone-implant integration of the screw were systematically evaluated and compared with those of the commercially available MILAGRO screw in an ovine ACL reconstruction model. The experimental screw exhibited adequate initial mechanical stability, gradual degradation, favorable biocompatibility and progressive bone ingrowth at the screw-bone interface. Its overall degradation and tissue integration profiles were comparable to those of the commercial control. In addition, a clinical study involving 64 patients demonstrated favorable functional outcomes at 6 months after ACL reconstruction, with no major implant-related adverse events observed. Collectively, these findings support the potential of the β-TCP/PLGA interference screw as a bioabsorbable fixation device for ACL reconstruction, combining mechanical stability with progressive degradation and bone integration.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers