Fluid-structure interaction analysis of aortic valve dynamics: effects of aspect ratio.
Xiyue Zhang, Liangqi Zhang, Zhong Zeng, Yibo Han, Xing Zhang, Xueli Wang, Quanchao Zhang, Guixue Wang
Department of Engineering Mechanics, College of Aerospace Engineering, Chongqing University, Chongqing 400044, China. · Key Laboratory for Biorheological Science and Technology of the Ministry of Education, National Local Joint Engineering Lab for Vascular Implants, College of Bioengineering, Chongqing University, Chongqing 400044, China.
Key points
From the paper's conclusion- We integrate the data from the Doppler experiments and the Windkessel model for the inlet velocity and outlet pressure conditions, respectively.
Abstract
The geometric configuration of prosthetic aortic valve is a key determinant of its mechanical response and associated hemodynamics during the cardiac cycle. In this work, high-fidelity fluid-structure interaction (FSI) analysis is conducted to provide physical insight into the effects of geometry on valve design. We integrate the data from the Doppler experiments and the Windkessel model for the inlet velocity and outlet pressure conditions, respectively. The arbitrary Lagrangian-Eulerian method is employed to address the two-way interaction between hyperelastic leaflets undergoing periodic large deformation and the surrounding blood flow. The effects of leaflet aspect ratio (AR) and blood non-Newtonian properties on mechanical performance are systematically investigated. The FSI analysis shows that increasing AR elevates von Mises stress, wall shear stress, blood velocity magnitude, transvalvular pressure gradient and regurgitation fraction (RF), while reducing geometric orifice area (GOA). These trends are opposite to the results from pure structural mechanical analysis. As AR increases from 0.86 to 1.26, the maximum von Mises stress increases by 58.66%, whereas GOA decreases by 71.54%. For the AR = 1.26 valve, the jet deviates from the centerline toward the lower vessel wall during peak systole and the subsequent deceleration phase, resulting in asymmetric deformation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Influence of Geometric Orifice Area on the Hemodynamic Performance of Prosthetic Aortic Valve DesignsDesigns · 2026
- Fluid-structure interaction analysis of leaflet-annulus geometric mismatch under progressive annular dilation: a parametric study using a pediatric aortic geometry.Medical engineering & physics · 2026
- Fluid dynamic characteristics and quantitative indicators of aortic valve calcification: A fluid-structure interaction study.Computer methods and programs in biomedicine · 2026
- Fluid-structure interaction simulation and analysis of the aortic valve under the condition of subaortic stenosis complicated with ascending aortic dilatation.Computer methods in biomechanics and biomedical engineering · 2026
- Experimental Bench Validation of a Computational Fluid-Structure Interaction Model of Transcatheter Aortic Valve DynamicsarXiv · 2026
- Anisotropic hyperelastic properties of porcine pericardium under equibiaxial loading: implications for aortic valve design.Frontiers in bioengineering and biotechnology · 2026