Artificial intelligence-based multimodal integration of ultrasound and digital breast tomosynthesis for breast-level risk classification.

Yujie Tan, Zhenjun Huang, Junwei Li, Ying Zhong, Qinyue Yao, Rui Chen, Yunfang Yu, Yaping Yang,

Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou 510000, China. · Department of Medical Oncology, Liuzhou People's Hospital, Guangxi Medical University, Liuzhou 545006, China.

Observational

Key points

From the paper's conclusion
  • These findings identify improved specificity as the principal added value of US-DBT and support its potential use as an adjunctive breast-level tool for refining positive imaging findings and prioritizing further diagnostic evaluation. Prospective validation in representative screening populations is required.

Abstract

BACKGROUND: Breast cancer imaging frequently combines ultrasound (US), digital mammography (DM), and digital breast tomosynthesis (DBT), yet integrating complementary findings remains labor-intensive. METHODS: We developed a parallel-branch deep learning framework for breast-level risk classification from paired US, DM, and DBT examinations. The models were trained on 2187 breasts and evaluated in an internal validation cohort of 632 breasts and an independent pathology-confirmed cohort of 500 breasts. Six single- and dual-modality models were compared. RESULTS: In the internal validation cohort, US-DBT achieved the highest observed area under the curve (AUC) of 0.944 (95% CI, 0.926-0.963), exceeding US-DM and DM-DBT but not US; its sensitivity was 0.860 (95% CI, 0.805-0.904) and specificity was 0.904 (95% CI, 0.871-0.930). In the pathology-confirmed cohort, US-DBT achieved an AUC of 0.934 (95% CI, 0.913-0.955), exceeding US and DM-DBT but not US-DM. Its specificity was higher than that of all three models (0.955; 95% CI, 0.927-0.975; all adjusted P < 0.001), with a positive predictive value (PPV) of 0.958 (95% CI, 0.931-0.977) and sensitivity of 0.850 (95% CI, 0.807-0.887), which did not differ significantly from any of the three models. Performance remained favorable in dense breasts, lesions <2 cm, and lower-suspicion Breast Imaging Reporting and Data System (BI-RADS) strata. CONCLUSIONS: These findings identify improved specificity as the principal added value of US-DBT and support its potential use as an adjunctive breast-level tool for refining positive imaging findings and prioritizing further diagnostic evaluation. Prospective validation in representative screening populations is required.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Artificial intelligence-based multimodal integration of ultrasound and digital breast tomosynthesis for breast-level risk classification — Science Skim