EP12.48 MRI sequence selection determines reliability of rapid volumetry in adult-type diffuse grade 2 glioma

Y Kwag, R Muraleetharan, O Lubbad, S Vundavalli, S Bucur, G Critchley

Observational · n=92

Key points

From the paper's conclusion
  • Conclusion MRI sequence selection, rather than the specific rapid measurement method, is the primary determinant of reproducibility in glioma volumetry.

Abstract

Background Accurate MRI-based volumetry in adult-type diffuse glioma informs surgical planning and RANO-based response assessment. However, inter-rater reproducibility across different sequences and rapid measurement methods remains poorly quantified in routine clinical workflows. Material and Methods This retrospective single-centre study included 92 adults with histologically confirmed adult-type diffuse grade 2 glioma (WHO 2021 criteria). Two trained raters independently performed Quick Volume (QV) and ellipsoid (EL) measurements on T1 (n = 54), T2 (n = 20), and T2-FLAIR (n = 11) sequences using Sectra IDS7 PACS. Primary outcomes included two-way random-effects ICC(2,1), Bland-Altman analysis, absolute percentage difference (APD), and agreement within ±25%. A linear mixed-effects model evaluated the independent and interactive effects of sequence and method on ln(APD + 1). Secondary analysis assessed accuracy against a trained manual segmentation reference using the Wilcoxon signed-rank test. Results T1 QV demonstrated the highest inter-rater reliability (ICC 0.979; median APD 13.8%) and most closely approximated the manual reference (median APD 8.3%, p < 0.001). T1 EL showed lower agreement and significant size-dependent bias (p = 0.002). In contrast, T2-based measurements showed substantial disagreement across both methods (ICC 0.865-0.886; median APD 32.2-37.8%), with only 35% of cases within the ±25% RANO threshold. The linear mixed-effects model confirmed a significant main effect of sequence (F[2,140.2] = 7.35, p < 0.001), with no independent effect of measurement method (p = 0.647) or interaction (p = 0.170). Compared with manual segmentation, T1 QV was significantly closer than T1 EL (median APD 8.3% vs 16.7%, p < 0.001). Conclusion MRI sequence selection, rather than the specific rapid measurement method, is the primary determinant of reproducibility in glioma volumetry. T2-based variability frequently exceeded the RANO progression threshold in this cohort, with potential implications for response classification. T1-based QV appears to provide a robust and clinically practical approach for standardised tumour quantification.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers