EP09.28 Quality assurance in a national randomized trial of radiation target volume reduction in glioblastoma: results from the contouring and dosimetry dummy run
D Di Perri, C De Laet, M Lambrecht, W Duthoy, L Grandjean, C Sweldens, C Mercier, M Govers,
Key points
From the paper's conclusion- Therefore, all participating centers were required to complete a dummy run (DR) assessing contouring and treatment planning prior to site activation.
Abstract
Background The BELGICA trial (NCT06719440) is a prospective, multicenter randomized phase III study evaluating a reduction of the Clinical Target Volume (CTV) margin from 15 mm (standard) to 10 mm (experimental) in patients with glioblastoma. The study aims to enroll 347 patients across 23 Belgian centers. Given the potential risk of increased marginal recurrence associated with CTV reduction, rigorous quality assurance of radiotherapy planning is essential. Therefore, all participating centers were required to complete a dummy run (DR) assessing contouring and treatment planning prior to site activation. Material and Methods Two benchmark cases were distributed via Oncoplace (Aquilab, Loos, France). The first focused on delineation of target volumes (GTV, CTV, PTV) and organs-at-risk (OARs). Adherence with protocol guidelines was assessed, and submitted contours were compared with a reference set using the Dice Similarity Coefficient (DSC). The second case required generation of a treatment plan that met the dosimetric constraints defined by the protocol. In case of deviations, investigators were required to revise and resubmit until validation was achieved. Results As of March 2026, 20 of 22 planned external sites completed the DR. For contouring, 12 sites were validated on first submission, 7 on second, and 1 on third. Major deviations included: incorrect inclusion of optic pathways in the CTV (n = 4), inclusion of T2/FLAIR abnormalities in the GTV instead of CTV (n = 2), and inaccurate GTV-to-CTV (n = 1) or CTV-to-PTV (n = 2) expansions. Mean DSC for GTV was 0.90 (range: 0.78-0.94) on first submission, and 0.91 (0.84-0.94) upon final validation. Mean DSC for CTV was 0.90 (range: 0.76-0.94) on first submission, and 0.92 (range: 0.88-0.94) upon final validation. Mean DSC for OARs were: eye L/R (0.91/0.90), brainstem (0.90), optic nerve L/R (0.73/0.70), pituitary gland (0.71), hippocampus L/R (0.70/0.67), cochlea L/R (0.63/0.68), hypothalamus (0.54), and optic chiasm (0.53). For planning, 17 sites were validated on first submission, and 3 on second. In all 3 cases, deviations were related to incorrect dose prescription (i.e., 40.05 Gy in 15 fractions rather than 60 Gy in 30 fractions). While all validated plans ultimately met protocol-defined constraints, significant inter-center variation in OAR sparing was observed, as illustrated by the contralateral hippocampus D40% (mean: 8.7 Gy; range: 4.3-25.0) and pituitary gland mean dose (mean: 29.9 Gy; range: 16.4-38.0). Conclusion The DR enabled identification and correction of major contouring and planning deviations prior to site activation. While all validated plans complied with protocol-defined mandatory constraints, the observed variability in OAR sparing may translate into differences in treatment-related toxicity. Comprehensive results and detailed dosimetric analyses will be presented at the meeting.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Parametric delineation of the clinical target volume for glioma: Model-based approach that tailors to physician contouring practices.Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology · 2026
- RADT-22 Clinical Outcomes and Dosimetric Findings from the GESTALT Study of GammaTile Combined with the Stupp Protocol in Newly Diagnosed Glioblastoma (NCT05342883)Neuro-Oncology · 2026
- Automated RANO 2.0-Aligned Response Assessment for Glioblastoma Clinical Trials: External Evaluation Against Expert Annotations.Cancers · 2026
- Agentic Automation of BT-RADS Scoring Using an End-to-End System for Standardized Glioma Follow-up Assessment.Radiology. Artificial intelligence · 2026
- PREDICT-GBM: A multicenter platform advancing personalized glioblastoma radiotherapy planning.NPJ digital medicine · 2026
- NCOG-25 Enhancing Tumor Volume Outperforms BT-RADS for Prediction of Radiographic Progression-Free Survival in GlioblastomaNeuro-Oncology · 2026