Neuro-Oncology

P05.02.B Optimizing biomarker diagnostics in CSF for primary CNS lymphoma: added value of repeated lumbar punctures and radiological determinants - a PRICELUS substudy

J L van Rooij, P H Wessels, N Kazouti, L van Schijndel, J M Niers, J E Bromberg, J M Gijtenbeek, R van Haastert,

Key points

From the paper's conclusion
  • We assessed (1) the added diagnostic value of repeated lumbar punctures for conventional CSF analyses (cytology and flow cytometry) and novel biomarkers (MYD88-CSF, IL10, CXCL13) in patients ultimately diagnosed with CNS lymphoma (CNSL), and (2) the association between radiological tumour characteristics and CSF biomarker levels and diagnostic performance.

Abstract

Background Primary central nervous system lymphoma (PCNSL) is typically diagnosed by brain biopsy, an invasive procedure associated with procedural risks and diagnostic delay. To reduce reliance on biopsy and enable CSF-based diagnosis in patients with radiological suspicion of PCNSL, a diagnostic algorithm incorporating MYD88 L265P mutation in CSF (MYD88-CSF), IL10 and CXCL13 has recently been developed. However, the added value of repeated lumbar punctures and the association between radiological tumour characteristics with biomarker levels are unknown. Material and Methods This study is a secondary analysis of the nationwide prospective PRICELUS cohort in the Netherlands, including patients with suspected PCNSL undergoing CSF evaluation. We assessed (1) the added diagnostic value of repeated lumbar punctures for conventional CSF analyses (cytology and flow cytometry) and novel biomarkers (MYD88-CSF, IL10, CXCL13) in patients ultimately diagnosed with CNS lymphoma (CNSL), and (2) the association between radiological tumour characteristics and CSF biomarker levels and diagnostic performance. Radiological features, including ventricular CSF contact, number of lesions, tumour volume, and maximum diameter, were determined by MRI segmentation with the nnInteractive tool. Results We included 50 patients with CNSL, of whom 44 (88%) had identifiable space-occupying lesions on imaging. Six patients (12%) had a positive result on the first lumbar puncture based on cytology or flow cytometry. A second lumbar puncture was performed in 35 CNSL patients, yielding one additional positive flow cytometry result (3%). No additional positive results were observed after a third lumbar puncture (n = 11). Biomarker levels were frequently elevated at the first lumbar puncture, with one additional patient converting to a positive IL10 result on repeat sampling (a different patient than the additional flow-cytometry-positive case). Ventricular CSF contact and tumour volume were associated with significantly higher leukocyte counts and protein levels, but we did not find an association with conventional diagnostics or with MYD88-CSF status, IL10, or CXCL13 levels Conclusion The added diagnostic value of repeated lumbar punctures appears limited for both conventional CSF diagnostics and novel biomarkers. Radiological tumour characteristics, including ventricular CSF contact, were not associated with CSF biomarker levels and did not enable stratification of patients likely to benefit from repeated CSF analysis. Based on these findings, a single lumbar puncture may be sufficient for both conventional and biomarker-based diagnostics in PCNSL, irrespective of radiological features, supporting early progression to tissue biopsy rather than repeated CSF sampling.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

P05.02.B Optimizing biomarker diagnostics in CSF for primary CNS lymphoma: added value of repeated lumbar punctures and radiological determinants - a PRICELUS substudy — Science Skim