P04.07.A Comparative evaluation of nanopore basecalling models for CNS tumor methylation profiling
A Miller-Michlits, Y Miller-Michlits, P Paplomatas, M Perkonigg, G Ranches, M Demetz, I Ebner, D Ardelianu,
Key points
From the paper's conclusion- High-accuracy basecalling provides the best balance between computational cost and diagnostic reliability, enabling classification within clinically relevant timeframes and supporting same-day CNS tumor diagnostics.
Abstract
Background Nanopore sequencing enables real-time detection of DNA methylation and is emerging as a promising approach for the rapid classification of central nervous system (CNS) tumors. Several computational tools translate nanopore-derived DNA methylation signals into diagnostic predictions, yet their comparative performance and dependence on upstream signal processing remain insufficiently characterized. Material and Methods We benchmarked three nanopore-based classification pipelines, MethyLYZR (naïve Bayes), Sturgeon (transfer-learned neural network) and NanoDx (crossNN neural network), using real-time sequencing data from fresh tumor biopsies (n = 56) and cerebrospinal fluid (CSF; n = 64). Sturgeon and MethyLYZR analyses used the first 90 minutes of sequencing data, while NanoDx used 3 hours for fresh tissue and 12 hours for CSF. All pipelines were evaluated using three basecalling models with distinct computational profiles: fast, high-accuracy (hac) and super-accuracy (sup). Performance metrics included classification concordance, confidence scores, CpG yield and runtime. Results Increasing basecalling accuracy modestly improved classification confidence albeit at increased computational cost, with runtimes rising ∼1.2× for hac and ∼1.6× for sup relative to fast across pipelines. Using pipeline-specific thresholds (nanoDx ≥ 0.2, Sturgeon ≥ 0.8, MethyLYZR ≥ 0.6), hac basecalling increased the number of classifiable samples, rescuing additional cases for nanoDx at the DNA methylation class level (n = 9) and for Sturgeon and MethyLYZR (n = 2 each), whereas sup provided no further gains. Family-level classifications for nanoDx and CpG yield remained largely unchanged. Sturgeon showed the shortest runtimes, MethyLYZR intermediate performance and NanoDx the highest computational burden, particularly for Pod5 input. Predictive scores increased by 1.02% from fast to hac and −0.44% from hac to sup, while mean runtime increased from 23.4 minutes (fast) to 28.4 minutes (hac) and 37.8 minutes (sup). At least one classifier yielded a diagnosis in 53/61 fresh tissue and 46/58 CSF samples using fast basecalling, increasing to 54/61 and 47/58 with hac, with no additional improvement using sup. Conclusion Basecalling strategy is a key determinant of performance in nanopore-based DNA methylation classification. High-accuracy basecalling provides the best balance between computational cost and diagnostic reliability, enabling classification within clinically relevant timeframes and supporting same-day CNS tumor diagnostics.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- EP05.11 Brain tumor diagnostics using nanopore sequencingNeuro-Oncology · 2026
- PATH-09 Prospective evaluation of nanopore sequencing for intraoperative and next-day CNS tumour molecular diagnosis: an extended single-centre cohortNeuro-Oncology · 2026
- Cross-cohort reproducibility of AI-assisted nanopore methylation profiling establishes diagnostic equivalence to WHO-integrated diagnoses in adult CNS tumorsmedRxiv · 2026
- EP17.11 Nanopore-based methylation profiling in neuropathological diagnosis:initialexperience from a Latin American centerNeuro-Oncology · 2026
- EP07.34 Nanopore sequencing for rapid classification of central nervous system malignanciesNeuro-Oncology · 2026
- Towards Democratizing CNS Tumor Classification: 10-fold reduction in methylation sequencing cost with the Flongle Flow CellmedRxiv · 2026