NCOG-26 Delivery of TTFields with head-flexible arrays: post-market analysis
Matthew Williams, Erika Cataldo, Franziska Oldenburg, Dina Daitchman, Gordon Chavez, Yair Horesh, Nick Avgeropoulos, Patrick Conlon,
Key points
From the paper's conclusion- Conclusion Assessment of post-market AEs demonstrated tolerable safety for TTFields delivered via HFE arrays.
Abstract
Background TTFields therapy delivers electric fields to tumors via skin-placed arrays. Most device-related adverse events (AEs) are mild-to-moderate skin reactions beneath the arrays. Higher device usage is associated with improved outcomes in clinical trials. Next-generation polymer-based arrays (HFE), lighter and more flexible than the previous generation (INE), are available and post-market experience is reported. Methods Unsolicited safety data were collected from routine post-market surveillance for patients with CNS tumors treated with TTFields using HFE arrays globally. For patients with newly diagnosed glioblastoma (GBM), time and region matched cohorts of patients initiating TTFields in 2024 (INE cohort) and 2025 (HFE cohort) were analyzed. AE data were assessed using MedDRA version 28.0. Administrative device records were used to track device discontinuation. Results In the full cohort (N = 8,284), 89% were treated for newly diagnosed GBM, 6% recurrent GBM, and 5% other brain malignancies. Median age was 58 (26–83) years and 63% of patients were male, reflecting real-world practice. All-cause and TTFields-related AEs occurred in 61% and 44% of patients, respectively. Most common device-related AEs were skin reactions (36%), heat sensation (6%), and electric sensation (6%). In the INE cohort (n = 1,972), rates of all-cause and device-related AEs were 67% and 52%, respectively. Skin reactions, electric, and heat sensation occurred in 37%, 13%, and 12% of patients, respectively, in the INE cohort and in 31%, 7%, and 8%, respectively, in the HFE cohort (n = 2,123). Incidence of non-device-related AEs was comparable between cohorts (INE: 15.7%; HFE: 15.0%). Device-related discontinuation was 21% and 17% with INE and HFE arrays, respectively. Conclusion Assessment of post-market AEs demonstrated tolerable safety for TTFields delivered via HFE arrays. Most device-related AEs were non-serious skin events; no systemic AEs were detected. Device-related AE and discontinuation rates were lower with HFE than INE arrays, suggesting improved tolerability, warranting extended follow-up.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- EP10.15 Safety and efficacy of Tumor-Treating Fields (TTFields) therapy for pediatric high-grade gliomaNeuro-Oncology · 2026
- EP12.29 Role of Device Support Specialists in TTFields for Newly Diagnosed Glioblastoma: Real-World Implementation and Integrated Patient, Healthcare Professional and Operational Perspectives in FranceNeuro-Oncology · 2026
- NCOG-24 Tumor Treating Fields therapy in newly diagnosed GBM patients with low performance status: real-world analysis of patients treated in the USNeuro-Oncology · 2026
- EP09.16 Preclinical Assessment of treatment scheduling for Tumor Treating Fields (TTFields) Applied Concurrently with Radiation Therapy in GlioblastomaNeuro-Oncology · 2026
- DDDR-13 Preclinical Assessment of Tumor Treating Fields (TTFields) Usage Schedules and Treatment Interruption Patterns in Cancer ModelsNeuro-Oncology · 2026
- EP18.32 Preclinical evaluation of Tumor Treating Fields (TTFields) efficacy under interrupted usage schedulesNeuro-Oncology · 2026