  • We hypothesized that 2D MRS using vendor-supplied acquisition and post-processing protocols will demonstrate comparably high sensitivity and specificity in differentiating PD from TC.

Abstract

2D MR spectroscopy (MRS) has emerged as a promising technique in differentiating progression of disease (PD) from treatment-related changes (TC) in the MRI evaluation of patients treated for high-grade gliomas or brain metastases. However, much of the existing MRS literature utilizes “home-grown” or third-party techniques for acquisition and image post-processing, which are not easily accessible for real-world neuroradiology practices. We hypothesized that 2D MRS using vendor-supplied acquisition and post-processing protocols will demonstrate comparably high sensitivity and specificity in differentiating PD from TC. We performed a single-center retrospective review of adult patients with high-grade gliomas or brain metastases undergoing post-treatment 2D MRS between 01/2024 and 01/2026. The “ground truths” were 3-month follow-up findings based on clinical, imaging, or pathology results. Of the 35 adult patients who received 2D MRS, 14 met our inclusion criteria. The patients’ mean age was 55.1 years, 8/14 patients (57.1%) were female, and 8/14 (57.1%) had primary high-grade gliomas. MRS findings for 13/14 (92.9%) patients aligned with their 3-month follow-up findings, with 9/13 (69.2%) showing TC and 4/13 (30.8%) showing PD. One patient with PD on MRS was deceased within 3 months. The one patient with discordant results showed TC on MRS but displayed clinical PD within 3 months. When compared to the gold-standard of 3-month follow-up, post-treatment 2D MRS correctly identified TC with a sensitivity of 100% and specificity of 80%. Our comparably high sensitivity and specificity of 2D MRS with vendor-supplied acquisition and post-processing software affirm the clinical utility and feasibility of incorporating 2D MRS into post-treatment brain MRI protocols in real-world neuroradiology and neuro-oncology practices without the need for complex home-grown software or research level expertise.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers