IMG-71 Real-time intraoperative imaging of 5-ALA/PPIX in glioblastoma using VISION - a chip-scale fluorescence contact imager
Nadia Allen-Gardizi, Jack Bartley, Micah Roschelle, Melike Pekmezci, Mitchel Berger, Jacob Young, Mekhail Anwar
Key points
From the paper's conclusion- Here we utilize VISION, a stand-alone, hand-held, millimeter-thin fluorescence contact imaging chip tailored for real-time intraoperative imaging of 5-ALA/PPIX at cellular-scale (125-µm resolution).
Abstract
The use of 5-aminolevulinic acid (5-ALA) enhances glioblastoma (GBM) resection by visualizing malignant cells, but its efficacy is limited in T2-FLAIR hyperintense regions due to sparse, infiltrative tumor cells. Better visualization of infiltrative glioma cells could improve supratotal resections and patient outcomes. Here we utilize VISION, a stand-alone, hand-held, millimeter-thin fluorescence contact imaging chip tailored for real-time intraoperative imaging of 5-ALA/PPIX at cellular-scale (125-µm resolution). Unlike conventional microscopes, VISION contacts tissue directly, sensing light at the tissue surface for high sensitivity, while its chip-scale form factor ensures maneuverability. We established proof-of-principle by imaging 5-ALA positive human GBM tissue from contrast-enhancing (CE), T2-FLAIR, and T1/T2 normal regions, defined by Brainlab intraoperative guidance. Resected tissues were initially categorized by surgeon assessment (5-ALA absent, weak, strong), frozen in OCT, sectioned to 5-µm thickness, and imaged with on a Zeiss Axio fluorescence microscope and VISION utilizing 10 mW/cm2 of 405nm laser light with a 200ms integration time. Consecutive H&E-stained and OLIG2/CD68 stained sections were evaluated by a neuropathologist to differentiate tumor cells from macrophages confounding 5-ALA uptake. Tissue sampled from regions without MRI abnormality showed no 5-ALA signal on either modality. FLAIR region tissue demonstrated weak 5-ALA fluorescence, yielding an average signal of 14 AU on microscopy and 0.10 AU on the VISION chip. CE tissue exhibited strong signals of 19 AU on microscopy and 0.17 AU on VISION. Crucially, in both FLAIR and CE samples, the spatial features and intensity distributions mapped 1:1 between microscopy and VISION. VISION accurately identified 5-ALA signals in sub-cellular thickness tissue slices in both FLAIR and CE regions in under 0.2 seconds. VISION provides sensitive, fast fluorescence imaging capable of detecting sparse GBM cells. Ongoing work aims to quantify 5-ALA signals by specific cell types and transition to fresh tissue imaging intraoperatively.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Intraoperative Tumor-Tissue Discrimination and Histology-Defined Glioma Grading Using Combined Fluorescence and Diffuse Reflectance Spectroscopy.Neuro-oncology · 2026
- OS13.6.A Delineation of the infiltration zone using intra-operative laserendomicroscopy in patients with glioblastomaNeuro-Oncology · 2026
- EP07.11 Fluorescence navigation and endoscopic assistance in surgery for brain glioblastomasNeuro-Oncology · 2026
- SURG-04 The NXDC-MEN-301 Study on 5-ALA for Meningiomas Surgery for the Assessing the Benefit of Intra-Operative Fluorescence ImagingNeuro-Oncology · 2026
- Short communication: Fluorescence preservation of protoporphyrin IX in fresh frozen glioma tissue.Brain & spine · 2026
- ANGI-07 Characterising the Glioblastoma 5-ALA resection margin at single cell resolutionNeuro-Oncology · 2026