Neuro-Oncology

IMG-65 Toward Automated Volumetric RANO 2.0: Reducing false positive new lesion detection due to evolving tumor morphology

Andie Gong, Robert V Masi, John Kim, Thomas Nelson, Gilbert Youssef, Patrick Y Wen, Chong Hyun Suh, Raymond Y Huang

Key points

From the paper's conclusion
  • We present methodology in reducing false positive errors in automated new lesion detection due to lesion-tracking errors from “splitting” tumor morphology, with direct applications in volumetric response assessment: our automated post-processing pipeline (FP-detector) is a proof-of-concept for a rule-based algorithm using subtraction maps, lesion/cluster centroids, and the Szymkiewicz-Simpson over

Abstract

Compared with conventional RANO 2.0 using perpendicular diameters, volumetric response criteria offer more reliable assessment of complex changes in tumor morphology. While time-consuming manual tumor segmentations have previously precluded the practical use of volumetric criteria, recent advances in automated lesion segmentation now make automated volumetric response assessment feasible. However, real-world utility of automated response assessment is limited by high rates of false positive new lesion detection (FP-NL), a major source of discordance between automated and human response assessment. Evolving tumor morphology in glioblastoma poses unique challenges in lesion tracking, particularly in “splitting” lesion morphology resulting in FP-NL, for example when: 1) a single primary lesion responding to treatment splits into multiple smaller lesions with decreased total volume, but automated lesion tracking inappropriately flags NL and calls progressive disease (PD), 2) evolving primary lesion morphology with similar total volume (not meeting PD criteria), but automated lesion tracking inappropriately flags NL in part or all of the primary lesion. We present methodology in reducing false positive errors in automated new lesion detection due to lesion-tracking errors from “splitting” tumor morphology, with direct applications in volumetric response assessment: our automated post-processing pipeline (FP-detector) is a proof-of-concept for a rule-based algorithm using subtraction maps, lesion/cluster centroids, and the Szymkiewicz-Simpson overlap coefficient. In our retrospective analysis of 450 patients (849 treatment segments) with new and recurrent glioblastoma, we compare FP-NL using our in-house end-to-end automated volumetric RANO 2.0 algorithm (Auto-RANO-3D), before and after the application of FP-detector. Of 376 lesions (209 patients, 328 scans) flagged as new and concerning for PD by Auto-RANO-3D, FP-detector correctly identified 138 of 171 errors with 88.7% accuracy (80.7% Se, 95.5% Sp), reducing the FP-NL rate from 46.0% to 14.7%. Our pipeline illustrates the utility of FP reduction methods in the development of fully-automated volumetric RANO response assessment.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers