IMG-54 International multicenter validation of a fully automated workflow for standardized FET PET assessment in brain tumors
Keith George Ciantar, Julia Hilgers, Jan-Michael Werner, Shaun D Grega, Nathaniel J Smith, Matthew E Larsen, Mark Tann, Wendy Territo,
Key points
From the paper's conclusion- We developed a fully automated FET PET analysis workflow and evaluated its performance against expert assessments in a large multicenter dataset.
Abstract
Background Amino acid PET using the tracer O-(2-[18F]fluoroethyl)-L-tyrosine (FET) is an important modality for brain tumor diagnostics, complementing MRI. We developed a fully automated FET PET analysis workflow and evaluated its performance against expert assessments in a large multicenter dataset. Methods 1,959 FET PET scans from 1,515 patients with brain tumors, centrally collected from five institutional cohorts acquired on 14 different scanners were evaluated: Germany I (Juelich/Aachen, n = 1647), Germany II (Munich, n = 88), USA (n = 86), Austria (n = 90), and the Netherlands (n = 48). Cohorts included scans acquired across different clinical indications and imaging settings. Our previously developed Juelich Segmentation Tool for Brain Tumor PET (JuST_BrainPET) was used for automated tumor segmentation, followed by brain extraction and post-processing to derive the background reference region. Background SUVmean (BG-SUVmean), tumor-to-background ratios (TBRmax, TBRmean), and PET-positive volume (PET-Vol) were computed according to PET RANO 1.0 recommendations and compared with expert assessments. Results Across all cohorts, the automated workflow demonstrated a high agreement with expert assessments despite variations in scanner hardware, acquisition protocols, and patient populations. Sensitivity for the correct detection of PET-positive lesions compared with expert assessments ranged from 85–100% and F1 scores, reflecting combined precision–recall performance, ranged from 90–96%. Quantitative FET PET parameters also showed strong correlations with expert assessments in all cohorts, including BG-SUVmean (r = 0.87–0.97), TBRmax (r = 0.90–0.98), TBRmean (r = 0.86–0.96), and PET-Vol (r, 0.92–0.99). Conclusions The automated workflow enabled standardized and reproducible evaluation of FET PET scans across multiple international cohorts, scanner types, and clinical settings supporting its potential for broad clinical implementation and multicenter harmonization of brain tumor PET imaging. Funding Supported by the German Research Foundation (DFG; project 428090865, SPP2177).
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- JS08.5.A Comparison of FET PET and contrast-enhanced MRI for tumor visualization in glioblastoma: a histopathology-validated studyNeuro-Oncology · 2026
- IMG-37 Prognostic relevance of FET PET in patients with newly diagnosed glioblastomaNeuro-Oncology · 2026
- [18F]FET PET enables histopathology-validated detection of non-contrast-enhancing glioblastoma.Nature communications · 2026
- P04.12.B Radiomics and machine learning for the differentiation of treatment-related changes from glioma relapse in patients with borderline findings in FET PETNeuro-Oncology · 2026
- EP03.36 Reconstruction matters: Influence of EARL standards and BSREM in [18F]FET PET for distinguishing glioma progression from treatment-related changesNeuro-Oncology · 2026
- P03.03.B Assessment of 18F-FET PET-based response to contemporary CNS-active systemic agents in patients with brain metastases using the PET RANO BM 1.0 criteriaNeuro-Oncology · 2026