Neuro-Oncology

PATH-77 Multi-modal deep learning for recurrence-risk stratification of silent corticotroph pituitary adenomas

Jasim Kada Benotmane, Florian Stockinger, Lucas Hoffmann, Daniel Delev, Roland Coras, Ingmar Blümcke, Franz Ricklefs, Matthias Dottermusch,

Computational · n=94

Key points

From the paper's conclusion
  • We developed HistNet, a multi-modal whole-slide-image model, with external testing in an independent cohort.

Abstract

Background Silent corticotroph pituitary adenomas (sc-PitNETs) recur in ≈20–30% of patients yet lack a serum biomarker, leaving postoperative imaging cadence without an evidence base. Existing deep-learning PitNET recurrence models pool heterogeneous lineages with modest discrimination; a silent-corticotroph-specific model is lacking. We developed HistNet, a multi-modal whole-slide-image model, with external testing in an independent cohort. Methods HistNet processes H&E + ACTH + Ki-67 whole-slide images through a frozen UNI ViT-L tile encoder, per-stain attention-based multi-instance learning (ABMIL), and Set-Transformer multi-modal fusion into a DeepSurv head. Six concept heads (proliferation index, Knosp grade, R0 resection, Cushing status, cavernous-sinus infiltration, pituitary-axis deficits) provide pathologist-interpretable anchors and regularise learning at small N. Development: n = 94 patients (23 recurrences; median follow-up 24 months); 5-fold × 5-member out-of-fold ensembling. Clinical comparator: L2-Cox on Knosp, MIB-1, R0, Cushing, and log-volume (100% coverage). External testing: n = 55, Universitätsklinikum Hamburg-Eppendorf. Results Out-of-fold predictions stratified patients into three risk tertiles with sharply separated 24-month recurrence rates: 0% (low; Wilson 95% CI 0–11%), 10% (mid), 29% (high); log-rank p = 1.94 × 10–5 versus p = 0.18 for the comparator. Net-benefit exceeded the comparator across most thresholds in the 5–30% range at 18 and 24 months. Concordance: 0.797 (95% CI 0.711–0.883) versus 0.737 (0.635–0.830). In-development calibration slope ≈ 1.00 post-recalibration; external calibration deferred (n = 25). Preliminary external testing was directionally consistent. A distilled H&E-only HistNet-mini student (∼70,000 parameters) achieved c = 0.71 (95% CI 0.54–0.84), supporting IHC-free deployment. Conclusions HistNet stratifies sc-PitNET patients into recurrence-risk tertiles (0%, 10%, 29% at 24 months) — supporting deferable surveillance at low risk and intensified follow-up plus early reintervention triage at high risk — outperforming the 5-feature clinical comparator on stratification and decision-curve net benefit, with preliminary external findings supportive. Prospective evaluation is warranted.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers