Neuro-Oncology

CTIM-21 Safety and feasibility of the Tumor Monorail Device (TMD) for serial tumor sampling at bedside in a trial of intratumoral D2C7-IT and an Fc-engineered anti-humanCD40 monoclonal antibody (2141-V11) administered via convection-enhanced delivery (CED) and cervical perilymphatic injections (CPLIs) of 2141-V11 in recurrent glioblastoma (rGBM) patients

Annick Desjardins, Nassir Mokarram, Sean Meehan, Shaili Sharma, James Herndon, Madison L Shoaf, Katherine B Peters, Margaret O Johnson,

Trial · n=61

Key points

From the paper's conclusion
  • Conclusion TMD implantation and serial sampling of tumor-associated material at multiple timepoints were feasible and well tolerated in patients with rGBM.

Abstract

Background The TMD is a bio-inspired implant lined with a nanofiber that, when placed into the tumor bed, guides invasive tumor cells into an extracranial reservoir, enabling serial interrogation of the reservoir for tumor sampling at the bedside. The TMD enables a more precise longitudinal assessment of tumor and microenvironmental changes pre- and post-treatment than current modalities, including imaging, potentially providing insight into treatment response and resistance mechanisms. To evaluate safety and feasibility, a TMD arm was incorporated into a trial of D2C7-IT+2141-V11 delivered by CED, followed by repeated CPLIs of 2141-V11 in rGBM (NCT04547777). Methods Eligible patients were adults with rGBM, ≥4 weeks from chemotherapy, bevacizumab, or investigational therapy, KPS ≥70%, and suitable for TMD implantation. The TMD was implanted into the non-enhancing tumor adjacent to the planned CED. Two to four weeks post-TMD implantation, patients received D2C7-IT (166μg) and 2141-V11 (3mg) CED, followed by 2141-V11 CPLI at weeks 2 and 4 and every 4 weeks thereafter. The TMD was sampled at each visit. Results We were able to safely implant the TMD in all 6 planned patients (males=3, females=3). Median age was 51.5 years (range, 42–56). No TMD-related dose-limiting toxicities occurred. TMD-related adverse events were limited to grade 1 events, including cognitive difficulties (n = 3), headache (n = 2), pain (n = 2), and one case each of dysphasia and seizure. As of 5/24/2026, 61 samples were obtained across 30 independent timepoints. Median sample volume was 0.2mL (range, 0–0.9mL). During the trial, TMD modifications were implemented to improve sample quality, including a decrease in needle gauge used for bedside sampling and a looser nanofiber configuration inside the reservoir. Conclusion TMD implantation and serial sampling of tumor-associated material at multiple timepoints were feasible and well tolerated in patients with rGBM. Correlative analyses comparing protein/cytokine profiles in plasma and tumor aspirates are ongoing.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers