RADT-35 Cochlear radiation dose predicts degree of functional hearing decline after fractionated stereotactic radiotherapy for vestibular schwannoma: A tiered dosimetric analysis of the 36 Gy and 40 Gy thresholds
LaToya McLean, Rafael Hernandez, Griffin O’Neill, Gretel Hernandez, Anish Chhabra, Yanmin Qu, Andres Haendel-Gonzalez, James Evans,
Key points
From the paper's conclusion- These results reinforce a cochlear dose constraint below 36 Gy and suggest WRS as a more informative endpoint than binary GR classification for quantifying functional hearing outcomes after FSRT.
Abstract
Objective Cochlear radiation dose predicts hearing loss after FSRT for vestibular schwannoma, yet most series report binary Gardner-Robertson (GR) grade pass/fail rather than quantifying actual decline. We performed a tiered dosimetric analysis across three cochlear dose strata—<36 Gy, 36–<40 Gy, and ≥40 Gy—using word recognition score (WRS) as the primary functional endpoint. Methods Retrospective multi-institutional FSRT study. Jefferson (N = 63) contributed full audiometric data; 46 non-overlapping GR I/II patients from an extended FSRT database (deduplicated) yielded a combined cohort of N = 94 GR I/II. UCLA FSRT cohort (N = 57, SRS excluded) provided GR-based validation. Endpoints: GR I/II hearing preservation (HP); ΔWRS and ΔPTA at short-term (3–6 months) and long-term (12–36 months); WRS preservation (baseline WRS >50%). Fisher’s Exact, Mann-Whitney U, and logistic regression were applied. Results Combined cohort (N = 94 GR I/II): HP rates fell stepwise—72.3% (<36 Gy), 46.2% (36–<40 Gy), 29.2% (≥40 Gy); <36 vs ≥ 40 Gy: OR = 6.35, p = 0.001. The binary cutoff (<36 vs ≥ 36 Gy) also reached significance (OR = 4.83, p = 0.001) but yielded a weaker association; three tiers retained as primary. GR I vs GR II HP: 67.2% vs 35.3% (OR = 3.76, p = 0.004). Jefferson cohort: median short-term WRS decline was 4 percentage points (pp) (<36 Gy), 6 pp (36–<40 Gy), and 36 pp (≥40 Gy) (p = 0.119)—a 32-pp gap. WRS preservation (WRS >50%): 72% vs 50% (<36 vs ≥ 40 Gy). Long-term logistic regression (dose + GR grade) predicted HP failure (χ²=12.19, p = 0.002). Conclusion Across a combined FSRT cohort, HP rates fell significantly across the 36 and 40 Gy thresholds (p = 0.001). A 32-pp WRS gap captures functional hearing loss not reflected in binary GR grading. GR II baseline is a strong adverse prognostic factor (OR = 3.76, p = 0.004). These results reinforce a cochlear dose constraint below 36 Gy and suggest WRS as a more informative endpoint than binary GR classification for quantifying functional hearing outcomes after FSRT.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- RADT-25 Longitudinal Hearing Outcomes and Cochlear Dosimetry in Vestibular Schwannoma: A Comparison of External Beam Radiotherapy Versus Stereotactic RadiosurgeryNeuro-Oncology · 2026
- Audiological Outcomes, Tinnitus, Quality of Life, and Tumor Size After Stereotactic Radiosurgery for Vestibular Schwannoma: A Prospective Study.Cureus · 2026
- Outcomes of Repeat Stereotactic Radiosurgery for Recurrent or Progressive Sporadic Vestibular Schwannoma: A Multicenter International StudyNeurosurgery · 2025
- Canal Filling Ratio Predicts Hearing Decline After Standardized Gamma Knife Radiosurgery for Vestibular Schwannoma.Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology · 2026
- Monitoring Hearing Function in Patients With Sporadic Vestibular Schwannoma: A Feasibility Study to Inform a Future Randomized Controlled Trial.Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology · 2026
- Cochlear Radiation Dose and Early Hearing Changes After Chemoradiotherapy for Head and Neck Cancer: A Single-Center Retrospective Cohort Study.Journal of clinical medicine · 2026