RADT-14 Fluoroethyltyrosine (FET)-PET in High Grade Glioma (HGG): Expanding the Boundaries of Viable Tumour Detection Beyond Conventional T1C MRI and its impact on CTV expansion
Narendra Kumar, Chitran Chakrabortty, Renu Madan, Rajinder Kumar, Manjul Tripathi, Sameer Vyas, Sourav Biswas, Debajyoti Chatterjee,
Key points
From the paper's conclusion- Conclusions FET PET is capable of detecting viable tumour beyond the T1 contrast-enhanced MRI-based GTV.
Abstract
Aims and Objectives To assess the impact of FET-PET in identifying viable tumour beyond T1-contrast-enhanced MRI–based GTV and to evaluate its potential role in reducing the GTV-to-CTV margin. Methodology Postoperative patients with HGGs were prospectively evaluated. One month after surgery, all patients underwent contrast-enhanced MRI of the brain, FET PET-CT, and contrast-enhanced CT simulation. Gross Tumour Volumes (GTVs) were contoured on contrast-enhanced CT after fusion with MRI and PET datasets. MRI-based GTVs were delineated according to the MD Anderson Cancer Centre (MDACC) guidelines. FET PET-based GTVs were defined using a threshold of 1.6 times the maximal tumour-to-background ratio (TBRmax), along with subjective contouring following consultation with Nuclear Medicine specialists. Clinical Target Volumes (CTVs) were generated through isotropic GTV expansions while respecting anatomical boundaries. Different margins were applied to generate various CTVs: MRI GTV +2 cm (MDACC) and FET PET GTV +0.5, +1.0, +1.5, and +2.0 cm. Statistical analysis was performed using IBM SPSS Statistics version 25. Paired comparisons employed t-tests and Wilcoxon signed-rank tests, with p < 0.05 considered statistically significant. Results A total of 33 patients were prospectively included between September 2025 and March 2026. FET-PET-derived GTVs were significantly larger than MRI-based GTVs (92.3 ± 49.4 cc vs 57.1 ± 35.1 cc), with a mean volumetric increase of 35.2 cc (95% CI: 27.3–43.0 cc), representing a 78.1% relative increase. Significant differences were observed on the paired t-test and Wilcoxon analysis (p < 0.001). Among the evaluated expansions, FET PET GTV +1.5 cm showed the strongest correlation with MRI-defined CTV (r = 0.915, p < 0.001). Conclusions FET PET is capable of detecting viable tumour beyond the T1 contrast-enhanced MRI-based GTV. A 2.0 cm expansion from the FET PET-based GTV overestimates the MRI-based CTV, whereas a + 1.5 cm expansion most closely approximates standard MRI-based CTV delineation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Volumetric discordance between ¹⁸F-FET-PET/MRI and MRI-based radiotherapy target volumes in high-grade glioma: a prospective pilot study (FETSMaRT).Journal of neuro-oncology · 2026
- JS07.7.A Prospective multisite FET-PET in Glioblastoma (FIG) Trial (TROG 18.06): Impact of FET-PET and MRI versus MRI alone on adjuvant radiotherapy volumes and dosimetryNeuro-Oncology · 2026
- JS08.5.A Comparison of FET PET and contrast-enhanced MRI for tumor visualization in glioblastoma: a histopathology-validated studyNeuro-Oncology · 2026
- Beyond a Universal Cut-Off: [18F]FET-PET Metrics for Distinguishing High-Grade Glioma Recurrence from Treatment-Related Changes.Brain sciences · 2026
- [18F]FET PET enables histopathology-validated detection of non-contrast-enhancing glioblastoma.Nature communications · 2026
- P03.05.B FET PET reveals considerable volumetric and spatial differences in tumor burden compared to conventional MRI in recurrent glioblastomaNeuro-Oncology · 2026