RADT-03 Postoperative Stereotactic Body Radiotherapy After Carbon-Fiber Instrumentation For Metastatic Spine Disease
Tobechukwu Ndika, Dominic Labella, Seeley Yoo, Trupti Trivedi, Brandon Lee, Eli Johnson, C Rory Goodwin, Trey Mullikin
Key points
From the paper's conclusion- These findings support the practicality of combining CFRP hardware with postoperative SBRT for metastatic spine disease and motivate prospective evaluation with longer follow-up.
Abstract
Background and Purpose Carbon-fiber-reinforced polymer (CFRP) implants minimize beam perturbation and imaging artifact relative to titanium, potentially enabling safer, more conformal postoperative SBRT to the spine. We evaluated feasibility, toxicity, and local control after postoperative SBRT delivered following neurosurgical procedures using CFRP instrumentation. Methods and Materials RR of patients who underwent decompression and/or stabilization with CFRP hardware followed by SBRT. We evaluated local recurrence and toxicity. Freedom from local failure (FFLF) from SBRT completion was estimated using Kaplan-Meier methods; patients without local recurrence were censored at lastfollow-up or death. Results Twenty-four patients (12 female, 12 male; median age 64, range 41-79) were treated at primarily thoracic targets. Nine patients had a prior course of radiotherapy at the site of interest. All courses used VMAT-SBRT: 3 fractions in 12/24 (50%) and 5 fractions in 12/24 (50%); median dose 27.5 Gy (range 21-35 Gy). Median time from surgery to RT start was 39.5 days (range 16-74). The cranio-caudal target length had a median of 70.5 mm (range 31-256 mm). Median follow-up from RT completion was 8.7 months (range 0.9-20.2). Primary histologies included renal cell (n = 8), melanoma (n = 3), breast (n = 3), non-small cell lung (n = 3), prostate (n = 2), sarcoma (n = 2), cervical (n = 1), colorectal (n = 1), and unknown primary (n = 1). Eighteen of 24 sites (75%) were free of in-field recurrence at last assessment. Estimated FFLF (Figure 1) was 77.4% (95% CI, 49.8-91.1) at 6-months and 67.8% (95% CI, 36.8-85.9) at 12-months. No grade ≥3 radiation-related acute or late toxicity at the treated levels were observed. Conclusion Postoperative VMAT-SBRT following neurosurgical procedures employing carbon-fiber instrumentation was feasible and delivered safely with no grade ≥3 toxicity in this cohort. Early local control was favorable (12-month FFLF 67.8%). These findings support the practicality of combining CFRP hardware with postoperative SBRT for metastatic spine disease and motivate prospective evaluation with longer follow-up.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Utilization of Carbon Fiber Spinal Instrumentation in Primary Spinal Tumors: Outcome Analysis from the AO Spine Primary Tumor Research and Outcomes Network.Global spine journal · 2026
- Robot-Assisted Placement of Thoracic Carbon-Fiber-Reinforced Polyetheretherketone (CFR-Peek) Pedicle Screws in the Cervical Spine for Giant Cell Tumor: Technical NoteBioengineering · 2026
- Multidisciplinary approach with stereotactic reirradiation to oligoprogressive spinal metastases from dedifferentiated osteosarcoma: a case report.Frontiers in oncology · 2026
- Feasibility of Using Short-Segment Instrumentation and Vertebral Body Reconstruction for the Treatment of Metastatic Disease in the Thoracic Spine.Journal of clinical medicine · 2026
- Stereotactic Body Radiotherapy for Spinal Metastases: Outcomes and Development of a Risk Assessment Score to Predict Local Tumor ProgressionNeurosurgery · 2026
- Outcomes following stereotactic body radiation therapy specific to spinal metastases with paraspinal disease extension: does volume matter?Journal of Neurosurgery Spine · 2025