From the paper's conclusion
  • Interim data demonstrate high concordance between 18F-RAD101 PET/CT and MRI, encouraging sensitivity for recurrent brain metastases, and favorable tolerability.

Abstract

Distinguishing tumor progression (TP) from radiation necrosis (RN) after stereotactic radiosurgery or radiotherapy for brain metastases remains challenging because conventional imaging has limited specificity. 18F-RAD101 is a novel Positron Emission Tomography (PET) radioligand targeting short-chain fatty acid metabolism in brain metastases, with low uptake in normal brain tissue. This open-label, single-dose, single-arm, multicenter Phase 2b study (NCT06777433) evaluates 18F-RAD101 PET in participants with suspected recurrence of previously irradiated brain metastases. Thirty-two ­participants received a single intravenous dose of 18F-RAD101 (≤370 MBq) followed by whole-brain PET/CT and a separate high-resolution MRI. The primary endpoint was concordance between 18F-RAD101 PET/CT and ­contrast-enhanced MRI on blinded central review. TP versus RN was determined by longitudinal imaging and/or histopathology within 6 months after 18F-RAD101 PET/CT. Secondary endpoints included diagnostic accuracy for TP versus RN, safety, tolerability, optimal dose, and pharmacokinetics. At the July 6 2026 interim data cutoff, 31 participants were evaluable for concordance. Patient-level agreement between PET/CT and MRI for all-lesion detection was 93.5% (Gwet’s AC1, 0.93; 95% CI, 0.82–1.00). Agreement for previously treated lesions was 83.9% (26/31; Gwet’s AC1, 0.78; 95% CI, 0.56–0.99). Quantitative agreement in tumor burden was strong (Lin’s CCC, 0.84; 95% CI, 0.70–0.92). Among 16 participants evaluable for diagnostic accuracy, sensitivity for recurrent metastatic disease was 85.7% (12/14; 95% CI, 57.2–98.2). Treatment-emergent adverse events were reported in 5/32 participants (15.6%), predominantly Grade 1; one Grade 2 headache occurred, and only two headache events were considered treatment-related. No treatment-emergent serious adverse events or clinically significant cardiac, hepatic, laboratory, or ECG abnormalities were observed. Interim data demonstrate high concordance between 18F-RAD101 PET/CT and MRI, encouraging sensitivity for recurrent brain metastases, and favorable tolerability. Final analyses, including specificity and longitudinal diagnostic performance on follow-up, are expected by the end of 2026.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers