SURG-37 Automated Labelling of D-Wave Waveforms Using an IONM Foundation Model
John Markert, Blake Perdikis, Nicolas Goff, Adhith Palla, Hammad Khan, Noa Langleben, Nikhil Mumaneni, Kimberly Markowitz,
Key points
From the paper's conclusion- These findings suggest that sequential waveform structure should be leveraged in future multimodal IONM models, with the potential to refine alarm criteria and support intraoperative decision-making at scale.
Abstract
Intraoperative neuromonitoring (IONM) lacks universal alarm criteria for waveform latency and amplitude for D-waves. Large-scale studies are hindered due to sparse patient populations, technical demands, and the difficulty of generating large specialist-guided waveform annotation datasets. In this study, we evaluated HiONM, a foundation model for IONM applications, on its ability to perform automated D-wave waveform annotation. The HiONM encoder was trained on 104,690 waveforms (53,563 MEP, 51,127 D-wave) from 244 patients across five spine procedure types, using a hierarchical contrastive loss over 250,000 steps, and was subsequently fine-tuned for D-wave amplitude and latency prediction on intramedullary spinal cord tumors and intradural extramedullary tumors. D-wave performance was evaluated on a prospective test set of 3,492 D-wave waveforms collected between November 2025 and March 2026, with expert-determined ground-truth labels. Across both model variants, the single-waveform model achieved a latency MAE of 0.504 ms (RMSE 0.737ms, r = 0.543), with 85.1% and 98.9% of predictions within ±1 ms and ±2 ms of ground truth. The triplet-mean model performed comparably on latency (MAE 0.518 ms, r = 0.539; ±1 ms: 84.2%), with near-zero bias in both models (+0.004 ms and +0.028 ms, respectively). However, the triplet-mean model substantially outperformed the single-waveform model on amplitude localization: mean IoU 0.595 vs. 0.336 and Dice 0.721 vs. 0.432, with markedly better onset accuracy (±1ms: 76.5% vs. 50.9%) and end-time accuracy (±1ms: 94.4% vs. 53.1%), demonstrating that temporal context improves amplitude window localization without compromising latency performance. To our knowledge, this is the first demonstration of automated D-wave latency and amplitude annotation achieving clinically relevant accuracy on a prospective dataset. Incorporating temporal context substantially improves amplitude localization while preserving latency performance. These findings suggest that sequential waveform structure should be leveraged in future multimodal IONM models, with the potential to refine alarm criteria and support intraoperative decision-making at scale.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Standardization of Neuromuscular Reflex Analysis—Role of Fine-Tuned Vision-Language Model Consortium and OpenAI gpt-oss Reasoning LLM-Enabled Decision Support SystemBiomechanics · 2026
- WPTNet-WPL: A Wave-Prior Transformer with Wasserstein Prior Learning for Interpretable Auditory Brainstem Response Assessment.IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society · 2026
- Data for Machine Learning Models: Clinical Experience Determines Interrater Reliability in Waveform Anomaly Detection.Neurocritical care · 2026
- Graph-Based Auditory Brainstem Response Threshold Estimation from Incomplete Intensity Series.Bioengineering (Basel, Switzerland) · 2026
- PHASE: A Physiology-Guided Hierarchical Foundation Model for Intracranial EEGarXiv · 2026
- Uncertainty-Aware Deep Learning Automates Artifact Correction for Clinical Body Surface Gastric Mapping at ScalemedRxiv · 2026