Effective Point Spread Function Estimation for ADF-STEM Resolution Enhancement Using an Atomically Thin 2D Reference.
Min-Chul Kang, Tae-Hoon Kim, Cheol-Woong Yang
School of Advanced Materials Science and Engineering, Sungkyunkwan University, 2066 Seobu-ro, Jangan-gu, Suwon, Gyeonggi-do 16419, Republic of Korea. · Department of Materials Science and Engineering, Chonnam National University (CNU), 77 Yongbong-ro, Buk-gu, Gwangju 61186, Republic of Korea.
Key points
From the paper's conclusion- We present an effective point spread function estimation workflow using an atomically thin two-dimensional reference.
Abstract
Scanning transmission electron microscopy (STEM) provides atomic-column images for structural and compositional analysis, but resolution is limited by probe broadening, residual aberrations, scan instability, specimen-dependent scattering, and noise. Recent computational approaches for recovering high-spatial-frequency information from experimental images include electron ptychography, machine-learning-based super-resolution, and deconvolution. Deconvolution provides a practical and physically interpretable route for conventional annular dark-field STEM because it directly uses an image-formation model and does not require additional four-dimensional data acquisition or training datasets. However, its reliability is governed by the point spread function used for reconstruction. We present an effective point spread function estimation workflow using an atomically thin two-dimensional reference. A monolayer MoS2 reference was used to reduce thickness-related multiple scattering and specimen-specific broadening, and its preprocessed experimental image was compared with a zero-aberration simulated image through gradient-based optimization of an effective point spread function. The estimated effective point spread function was applied to Si [110] and Nd2Fe14B [100] images acquired under closely matched imaging conditions, extending detectable Fourier information in Si and revealing an intensity feature at the expected Fe-column position between Nd columns. These results demonstrate that the proposed approach can serve as a complementary method for improving the interpretability of conventional STEM imaging.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Learning Spatially Adaptive Blur Representations for Stable Deconvolution in Electron Microscopy.Annals of the New York Academy of Sciences · 2026
- Spatial-Frequency Learning for Scanning Transmission Electron Microscopy Image Enhancement.IEEE transactions on pattern analysis and machine intelligence · 2026
- Optimization-Based Thickness Estimation and Depth-Resolved FIB-Induced Damage Characterization via Multislice Electron PtychographyarXiv · 2026
- Towards Self-Optimizing Electron Microscope: Robust Tuning of Aberration Coefficients via Physics-Aware Multi-Objective Bayesian Optimization.Microscopy and microanalysis : the official journal of Microscopy Society of America, Microbeam Analysis Society, Microscopical Society of Canada · 2026
- On the accuracy of atomic-resolution electrostatic measurements in 2D materials.Ultramicroscopy · 2026
- Optical point-spread function via defocus phase retrieval in scanning electron microscopy.Micron (Oxford, England : 1993) · 2026