Oesophageal perforation secondary to denture ingestion requiring thoracotomy and T-tube placement: a rare case report.
Konstantinos Baronos, Seohyun Lee, Sara Arshad, Marios Alogakos, Rami Ayoub, Christopher Sutton, David Bowrey
Department of General Surgery, University Hospitals of Leicester NHS Trust, Infirmary Square, Leicester, LE1 5WW, United Kingdom. · Department of Surgery, Indiana University, Emerson Hall, 545 Barnhill Drive, Indianapolis, IN, 46202, United States.
Key points
From the paper's conclusion- We present a 69-year-old female who accidentally ingested a denture.
Abstract
Oesophageal perforation from foreign body ingestion is a life-threatening emergency. Dentures pose particular risk due to irregular shape, size, and radiolucency. We present a 69-year-old female who accidentally ingested a denture. Radiography identified the foreign body at C4/C5. Endoscopic retrieval failed due to mucosal embedding, and a through-and-through oesophageal tear was confirmed. She underwent emergency right thoracotomy with denture retrieval. Given localized inflammation, a 4 cm perforation, and pneumomediastinum, a T-tube was placed across the defect instead of primary repair. Post-operatively, she required intensive care, enteral feeding, and prolonged chest drainage. Recovery was complicated by suspected mediastinitis, candidiasis, and deconditioning, but she ultimately tolerated oral intake and was discharged. In complex thoracic OP with inflammation or a large defect, T-tube placement offers a reliable, oesophagus-preserving alternative to primary repair. This case highlights the diagnostic challenges of radiolucent dentures and the importance of multidisciplinary decision-making.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Swallowed dental prosthesis causing late oesophageal obstruction and tracheo-oesophageal fistula in a young patient.Journal of surgical case reports · 2026
- Missing Denture: CT-Negative Radiolucent Non‑clasp Resin Partial Denture Retained in the Stomach for 10 Days.Cureus · 2026
- Esophageal Perforation During Dilation in a Patient With Hypopharyngeal Metastatic Squamous Cell Carcinoma.Cureus · 2026
- The Clinical Characteristics and Management of Dental-Related Foreign Body Accidents: A Retrospective Observational Study.Healthcare (Basel, Switzerland) · 2026
- Complete Migration of Metallic Plate in a Pseudodiverticulum of Cervical Esophagus.Surgical case reports · 2026
- Thoracoscopic Primary Repair for Spontaneous Esophageal Rupture in a Patient With Acute Irreducible Inguinal Hernia: A Case Report.The American journal of case reports · 2026