Type III endoleaks following endovascular aortic repair: a case series.
Buraq Ahmed, Oliver Chan, Maite Del Campo Martinez, Hariesha Pathmaraj, Chris Grieco
School of Clinical Medicine, University of Cambridge, Addenbrooke's Hospital, Hills Rd, Cambridge CB2 0SP, United Kingdom. · School of the Biological Sciences, University of Cambridge, 17 Mill Lane Cambridge CB2 1RX, United Kingdom.
Key points
From the paper's conclusion- These cases show type III endoleaks may be radiologically subtle yet rapidly fatal, sac stability alone should not determine management, and complex arch morphology demands tailored device selection and access planning.
Abstract
Type III endoleaks, from disconnection between modular stent-graft components (type IIIa) or fabric defects within a limb (type IIIb), are uncommon but potentially life-threatening, transmitting systemic pressure into the aneurysm sac and carrying a high rupture risk. We describe three men with late type III endoleak failure after complex thoracic aortic repair. One presented with rupture at a mid-thoracic modular overlap, salvaged by emergency relining via a hostile femoral cut-down. A second, under surveillance for an asymptomatic endoleak managed conservatively given a static sac, later ruptured at a separate site and died despite emergency relining. A third developed a type IIIb fabric failure in a highly angulated aortic arch, salvaged using a conformable stent-graft and left-ventricular through-and-through wire support. These cases show type III endoleaks may be radiologically subtle yet rapidly fatal, sac stability alone should not determine management, and complex arch morphology demands tailored device selection and access planning.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Late Type IIIa Endoleak Despite Adequate Component Overlap after AFX2 EVAR: A Report of Two Cases.Annals of vascular diseases · 2026
- Six-Year Survival without Open Conversion after Repeat Endovascular Repair for Rupture Associated with Endograft Infection following EVAR: A Case Report.Annals of vascular diseases · 2026
- Endovascular Salvage of Late Type IA Endoleak After Ascending Aortic TEVAR for Ruptured Penetrating Ulcer.JACC. Case reports · 2026
- Endovascular Management of Aorto-iliac Bifurcation Rupture.Interventional radiology (Higashimatsuyama-shi (Japan) · 2026
- Ten-year experience in the endovascular repair of complex and thoracoabdominal aortic aneurysms by an off-the-shelf multibranched thoracoabdominal endograftJournal of Vascular Surgery · 2025
- Endovascular Rescue of Type III Endoleak From an Abandoned Fenestration After Fenestrated Endovascular Aneurysm Repair.JACC. Case reports · 2026