Current practices and challenges in inverse planning for gynecologic brachytherapy: insights from a multi-institutional study.
Hiroyuki Okamoto, Ayaka Nagao, Masahiro Morimoto, Setsuo Tamenaga, Yoshihiro Ueda, Tomoko Kawamura, Noriko Ii, Kenji Yoshida,
Section of Radiation Safety and Quality Assurance, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo 104-0045, Japan. · Department of Radiation Oncology, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo 104-0045, Japan.
Key points
From the paper's conclusion- These findings highlight the need for planning QA that incorporates dwell-time review in addition to DVH parameters, and provide a foundation for optimizing and standardizing IP in gynecologic BT to improve planning reproducibility and patient outcomes.
Abstract
This study investigated the feasibility and reproducibility of inverse planning (IP) in gynecologic high-dose-rate brachytherapy (BT) across ten institutions (five IP and five manual). Two pre-defined cases (high-risk clinical target volume, CTVHR: 62.8 and 27.4 cm3) included the organs at risk (OARs), a tandem, ovoids, and 8 and 3 interstitial needles, respectively. Each institution generated BT plans according to its policy, assuming 30 Gy/15 fractions of whole-pelvis irradiation and 20 Gy/10 fractions of central shielding. Plans were evaluated using dose-volume histogram (DVH) parameters. Dwell-time distributions were compared with conventional Manchester-based pear-shaped plans to identify deviations (e.g. needle dominance and high-dose characteristics) that may not be captured by DVH alone. Institutional interviews assessed clinical acceptability and optimization strategies. All plans were considered clinically acceptable, with no significant differences between IP and non-IP groups in CTVHR D90% and OARs ${{D}}_{{2}\ {\mathrm{cm}}^{{3}}}$. IP institutions used institution-specific strategies to preserve uterine dose conformity, including fixing dwell times for selected applicators and applying optimization constraints based on Manchester-derived contours, delineated ovoids or delineated uterine structures. Overall, IP plans were comparable to non-IP plans for CTVHR D90%, CTVHR V100% (cm3) and OARs ${{D}}_{{2}\ {\mathrm{cm}}^{{3}}}$. In contrast, differences in dose distribution around the uterine fundus and the wide range of the body V100% (cm3) suggested varying institutional strategies for fundus dose. These findings highlight the need for planning QA that incorporates dwell-time review in addition to DVH parameters, and provide a foundation for optimizing and standardizing IP in gynecologic BT to improve planning reproducibility and patient outcomes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Gynecologic hybrid and interstitial high-dose-rate brachytherapy.Brachytherapy · 2026
- Prospective Paired Comparison of MRI- and CT-Based Planning for Adjuvant Vaginal Cuff Brachytherapy in Endometrial Cancer: An Exploratory StudyRadiation · 2026
- Centralization of MR image-guided adaptive brachytherapy for cervical cancer in Austria: feasibility and outcomes.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2026
- Implementing Image-Guided Brachytherapy (IGBT) For Cervical Cancer in Resource-Limited Settings: An International Multicentric Cross-Sectional Study of Resource and Workflow Impact.International journal of radiation oncology, biology, physics · 2026
- Image-Guided Adaptive Brachytherapy Using Patient-Specific 3D-Printed Templates for Complex Locally Advanced Cervical Cancer: A Real-World Implementation Study.Cancers · 2026
- Comparative effectiveness and safety of magnetic resonance imaging-guided adaptive brachytherapy versus conventional brachytherapy in locally advanced cervical cancer: a systematic review and meta-analysisFrontiers in Oncology · 2026