Renal Volume Measurement in ADPKD: Agreement of SuperWide View and 3D Ultrasound Techniques with CT.
Satomi Omotehara, Takahito Iwai, Mutsumi Nishida, Fumihiko Hattanda, Saori Nishio, Yusuke Kudo, Naoki Yamashita, Takanori Teshima
Division of Laboratory and Transfusion Medicine, Hokkaido University Hospital, N14, W5, Kita-ku, Sapporo 060-8648, Japan. · Management Strategy Department, Hokkaido University Hospital, N14 W5, Kita-ku, Sapporo, 060-8648, Japan.
Key points
From the paper's conclusion- We evaluated the agreement of SWV 2D and S3D kidney volume measurements with CT-derived volumes.
Abstract
BACKGROUND: Magnetic resonance imaging is recommended for kidney volume assessment in autosomal dominant polycystic kidney disease (ADPKD), although computed tomography (CT) is also commonly used. Ultrasound (US) is noninvasive, but kidney enlargement often exceeds the probe width. SuperWide View (SWV) extends the field of view, whereas Sensor 3D (S3D) enables volumetric measurement. We evaluated the agreement of SWV 2D and S3D kidney volume measurements with CT-derived volumes. METHODS: We enrolled 67 patients with ADPKD who underwent US and CT within 3 months. Two sonographers independently measured kidney volumes using SWV 2D and S3D with 2, 4, and 8 cross-sectional planes. Correlations, intraclass correlation coefficients (ICCs), percentage errors, and Bland-Altman analyses were performed. RESULTS: All US methods correlated strongly with CT measurements (r ≥ 0.89, p < 0.0001), with ICCs of 0.875-0.952. The 4-plane S3D method had the lowest median percentage errors (Examiner A, 3.8%; Examiner B, -1.0%). Overall, 65.3% and 61.8% of measurements, respectively, were within ±15% of CT-derived values. No fixed bias was observed, however, the Bland-Altman limits of agreement were relatively wide. CONCLUSIONS: S3D US showed strong correlations with CT-derived kidney volumes. However, the relatively wide limits of agreement and the finding that only approximately 62-65% of 4-plane measurements were within ±15% of CT-derived values indicate that US and CT measurements are not interchangeable at the individual-patient level. S3D US may nevertheless provide a useful noninvasive approach for kidney volume assessment in selected patients with ADPKD.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Assessment of autosomal dominant polycystic kidney disease severity using deep learning-based kidney volumetry in CT.European radiology experimental · 2026
- A rapid automated segmentation method for total kidney volume measurement on unenhanced computed tomography in autosomal dominant polycystic kidney disease.Abdominal radiology (New York) · 2026
- Stone density measurement on NCCT: 2D ROI versus semi-automated 3D methods for predicting shock wave lithotripsy success.Urolithiasis · 2026
- Less is More: Robotic Kidney Transplantation in Polycystic Kidney Disease Without Preemptive or Simultaneous Native Nephrectomy.The international journal of medical robotics + computer assisted surgery : MRCAS · 2026
- A z-score-based reference system for renal volume using three-dimensional ultrasound: from model to clinical tool.Quantitative imaging in medicine and surgery · 2026
- Downstream-Aware Automated QC of Images and AI-Generated Segmentations.Journal of imaging informatics in medicine · 2026