Journal of Mechanics

Vibration calculation of overhead conductor based on transfer matrix model

Si Jiajun, Wang Zian

Key points

From the paper's conclusion
  • The results confirm the effectiveness and reliability of the proposed model for describing the dynamic characteristics of conductor-damper system.

Abstract

Overhead transmission lines are critical components of the power grid. Long-span conductors are particularly susceptible to wind-induced vibrations in service, which can lead to fatigue damage and strand breakage. A coupled conductor-damper model is developed using the transfer matrix method, and the resonance frequencies and energy-dissipation characteristics of the system are investigated. A full-scale laboratory vibration test setup is built and excitation experiments are carried out to measure the resonance frequencies, input powers, and vibration amplitudes of the conductor-damper system. The theoretical model reproduces the main trends observed in the experiments, including the two coupled resonance frequencies of the damped system and the variation of the wind input power and vibration amplitude with frequency. The results confirm the effectiveness and reliability of the proposed model for describing the dynamic characteristics of conductor-damper system.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers