Performance of multiple multi-cancer detection tests using a large independent reference set (Alliance A212102)
Marie Wood, Paul F. Pinsky, Paul J. Novotny, Elyse Leevan, Matthias Weiss, Dan Edelman, Mark Watson, Christos Patriotis,
University of Colorado Cancer Center · National Cancer Institute
Key points
From the paper's conclusion- Five hundred and forty nine cases (encompassing 13 cancer types) and 413 controls from the reference set were included in the study.
Abstract
BACKGROUND: Reference sets are needed to evaluate performance of multi-cancer detection (MCD) assays. The National Cancer Institute funded the Alliance reference set study to assess MCDs for use in future trials. METHODS: Individuals with cancer and controls were recruited; blood specimens were collected prior to cancer treatment. A performance evaluation study was designed utilizing reference set samples. Companies (n = 6) were selected to participate based on review of performance data and ability to utilize the blood collection tube. Companies received samples from cancer types their assay was designed to detect ("targeted"), plus additional "non-targeted" and control samples. Companies reported positive/negative calls, risk scores, and tissue-of-origin (TOO) predictions. Sensitivity was computed for early (I-II) and late (III-IV) stage cases, based on positive/negative calls (SEPN) and at fixed 98% specificity (SE98). Specificity and TOO accuracy were computed. RESULTS: Five hundred and forty nine cases (encompassing 13 cancer types) and 413 controls from the reference set were included in the study. Companies assessed samples from median 6 (range 5-9) targeted cancer types and median 8 (range: 7-11) overall cancer types. Median (range) specificity was 92.3% (76.5%-98.5%). Median (range) SEPN was 32% (25%-42%) for early stage and 73% (48%-89%) for late stage; while median (range) SE98 was 19% (8%-35%) for early stage and 66% (13%-79%) for late stage. Median sensitivity for non-targeted types was 40% (early stage) and 52% (late stage). Median (range) TOO accuracy (primary predicted site) was 75% (64%-78%). CONCLUSIONS: Sensitivity and specificity varied widely across assays with early-stage sensitivity substantially lower than late-stage sensitivity. CLINICAL TRIAL REGISTRATION NUMBER: ClinicalTrials.gov identifier NCT05334069.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Real-world data and clinical experience from over 100,000 multi-cancer early detection testsNature Communications · 2025
- Performance and safety of a multi-cancer early detection test: the PATHFINDER 2 study.Nature medicine · 2026
- Performance of a multi-biomarker class, multi-cancer early detection (MCED) blood test in a prospectively collected cohort.Cancer epidemiology, biomarkers & prevention : a publication of the American Association for Cancer Research, cosponsored by the American Society of Preventive Oncology · 2026
- Performance of a multi-cancer early detection test in the randomized controlled NHS-Galleri trial.Nature medicine · 2026
- Projected impact of population-level multi-cancer early detection screening: a discrete event simulation analysis.Journal of the National Cancer Institute · 2026
- Multicancer Detection Tests for Population-Wide Screening of Asymptomatic Individuals: A Systematic Review.JCO oncology practice · 2026