EP1.64 Three-Zone Planning (3Z) for Spherical Periacetabular Osteotomy: A Structured Framework for Quantitative Acetabular Reorientation
Dr Takkan Morishima, Dr Kohei Hashimoto, Dr Yukio Nakamura, Dr Nounori Takahashi
Key points
From the paper's conclusion- We developed a three-zone planning (3Z) concept that partitions the spherical osteotomy into superior (SZ), joint (JZ), and inferior (IZ) zones, integrated with CT-based navigation, to provide a quantitative and reproducible framework for SPO.
Abstract
Background Spherical periacetabular osteotomy (SPO) preserves pelvic ring continuity while enabling three-dimensional acetabular reorientation in developmental dysplasia of the hip (DDH). However, the osteotomy trajectory and fragment motion have traditionally been defined qualitatively, limiting reproducibility and hindering wider adoption. We developed a three-zone planning (3Z) concept that partitions the spherical osteotomy into superior (SZ), joint (JZ), and inferior (IZ) zones, integrated with CT-based navigation, to provide a quantitative and reproducible framework for SPO. Methods Between July 2019 and December 2024, 17 patients (18 hips) with symptomatic acetabular dysplasia underwent SPO using 3Z at a single institution. Mean age was 37 years (range, 16–59); 16 hips were female. The osteotomy trajectory was divided into SZ, JZ, and IZ on patient-specific 3D CT models, with "crossroad" contact points defined in the SZ to simulate the planned rotational arc. CT-based navigation (Stryker OrthoMap 3D) reproduced the planned cuts intraoperatively, and the acetabular fragment was fixed with bioabsorbable screws. Standardized anteroposterior radiographs were obtained preoperatively, immediately postoperatively, and at 6–12 months. Radiographic parameters included LCEA, Sharp angle, ARO, and LLD. Results Radiographic correction was achieved in all 18 hips. LCEA improved from 10.1° ± 9.0° to 31.5° ± 5.9°. Sharp angle decreased from 48.8° ± 4.0° to 40.0° ± 3.5°, and ARO improved from 19.1° ± 9.3° to 0.0° ± 5.3°. Mean structural shortening was 3.54 ± 3.74 mm; no patient reported symptomatic LLD. No deep infection, nonunion, pelvic ring fracture, or major vascular injury occurred. Transient femoral nerve palsy occurred in 5 hips, all of which resolved spontaneously. Conclusions The 3Z concept combined with CT-based navigation provides a structured and reproducible framework for SPO, enabling consistent acetabular correction while maintaining pelvic ring stability. Beyond SPO, 3Z is potentially adaptable to RAO and PAO by redefining zone boundaries, offering a common geometric platform for hip preservation surgery.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- TP4.5 Precision Without Navigation: Standardized C-Arm Positioning Improves Accuracy in Periacetabular Osteotomy Surgical ModelJournal of Hip Preservation Surgery · 2026
- TP4.3 Accuracy of Patient Specific Guide to Achieve Pre-Operatively Templated Correction of Hip Dysplasia with PAOJournal of Hip Preservation Surgery · 2026
- EP1.41 Sagittal Orientation of the Acetabulum in Hip Dysplasia: A Missing Parameter in Periacetabular Osteotomy PlanningJournal of Hip Preservation Surgery · 2026
- FP7.2 Patient-Specific Osteotomy Plane Configuration Optimises Femoral Head Coverage and Bone Overlap in Bernese Periacetabular Osteotomy for Hip Dysplasia: A Three-Dimensional Simulation StudyJournal of Hip Preservation Surgery · 2026
- TP1.2 Increased correction of lateral centre edge angle after periacetabular osteotomy is associated with a reduction in hip flexion and internal rotation: A three-dimensional computed tomography simulation studyJournal of Hip Preservation Surgery · 2026
- EP1.91 The Effect of Pelvic Tilt on Radiographic Measures of Acetabular CoverageJournal of Hip Preservation Surgery · 2026