Use of the Guardian table extension during periacetabular osteotomy is associated with an increased risk of intraoperative posterior column fractures.
Ta-Wei Tai, Emil Varas-Rodríguez, Emmanouil Grigoriou, Sergio F Guarin Perez, Diego J Restrepo, Rafael J Sierra
Department of Orthopedics, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, 138, Shengli Rd., North Dist., Tainan City 704, Taiwan. · Department of Orthopedic Surgery, Mayo Clinic, 200 First St. SW Rochester, MN 55905, United States.
Key points
From the paper's conclusion- These findings suggested that the Guardian table extension system was associated with increased risk of posterior column fractures, likely due to lack of distal support and stability.
Abstract
The Guardian table is widely utilized for combined hip arthroscopy and periacetabular osteotomy (PAO) due to its postless traction design and the ability to perform both procedures without the need for redraping. This retrospective cohort study reports one surgeon's use of the Guardian table extension during combined hip arthroscopy and PAO and the occurrence of intraoperative posterior column fractures. Seventy-two consecutive PAO procedures performed at a single institution between February 2023 and January 2025 were analysed. Procedures involving concomitant hip arthroscopy (n = 26) utilized the Guardian table, whereas those without arthroscopy (n = 46) used a conventional radiolucent table. Patient demographics, clinical data, and complications were reviewed. Additionally, mechanical testing quantified table stability by measuring peak absolute acceleration ('table bounce') using accelerometry during simulated malleting. The incidence of intraoperative posterior column fractures was significantly higher with the Guardian table (4/26, 15.4%) compared to the conventional table (0/46, 0%; P = .0062). Mechanical testing demonstrated significantly greater table bounce for the Guardian table (69.1 ± 3.4 m/s2 versus 28.2 ± 4.4 m/s2, P < .001). Patient characteristics and surgical complexity did not differ significantly between fracture and non-fracture cases. These findings suggested that the Guardian table extension system was associated with increased risk of posterior column fractures, likely due to lack of distal support and stability. Surgeons should consider alternative table setups or intraoperative support modifications to mitigate this risk during PAO procedures.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Incidence and risk factors for postoperative posterior column fractures following periacetabular osteotomy.Journal of hip preservation surgery · 2026
- EP9.21 Protecting the Sciatic Nerve During Periacetabular Osteotomy: Techniques Currently Taught in Hip Preservation Fellowship ProgramsJournal of Hip Preservation Surgery · 2026
- Association of Surgical Approach with Intraoperative Femoral Fracture Patterns During Cementless Hemiarthroplasty for Femoral Neck Fracture.Journal of clinical medicine · 2026
- Carbon fiber traction table use is associated with a lower incidence of stress shielding and cortical hypertrophy after total hip arthroplasty: a case-control study.BMC musculoskeletal disorders · 2026
- FP1.5 Variation Between Supine and Standing Pelvic Tilt in Patients Undergoing Periacetabular Osteotomy (PAO)Journal of Hip Preservation Surgery · 2026
- EP1.60 Re-examining the association between labral size and hip dysplasia: Does a clear trend emerge?Journal of Hip Preservation Surgery · 2026