Key points
From the paper's conclusion- This study included eighteen patients with a mean ± SD TBSA burn of 41.7% ± 20.2%, contributing 387 recommendations in Phase 1 and 380 in Phase 2.
Abstract
Crystalloid resuscitation is central to severe burn care. Traditional approaches rely on calculated formulae, monitoring, and endpoint guided titration. Computerized Clinical Decision Support (CDS) tools automate this process and improve goal-directed outcomes, but use remains limited due to accessibility. Large Language Models (LLMs) offer an unevaluated alternative. This study compared crystalloid estimates between a commonly used LLM and CDS system. A retrospective one-year two phase analysis was conducted for adult patients treated at an ABA-verified burn center who received individualized CDS-guided fluid resuscitation during the first 24 hours after injury. An LLM was queried using standardized prompts based on identical clinical inputs used by the CDS tool, including age, TBSA, weight, formulae, urine output, and confounders. Bland-Altman analysis assessed fluid volume predictions between the LLM and CDS system. This study included eighteen patients with a mean ± SD TBSA burn of 41.7% ± 20.2%, contributing 387 recommendations in Phase 1 and 380 in Phase 2. Mean LLM and CDS system rates through 24 hours post-burn were not statistically significant different (462 ± 318 mL/hr vs 450 ± 288 mL/hr; p=0.57). Correlation between the two systems was strong (r=0.93; 95% CI, 0.91-0.94, p<0.0001) with a mean difference of 12.3 mL/hr (95% limits of agreement, -222 to 246 mL/hr). Following prompt refinement, Phase 2 correlation remained strong (r=0.94; 95% CI, 0.93-0.95, p<0.0001) with a mean difference of -23.4 mL/hr and limits of agreement ranging from -178.3 to 131.5 mL/hr. LLMs can generate sequential fluid-rate recommendations during simulated burn resuscitation, but variability in fluid rates highlight the need for further refinement and clinical validation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- BurnCare: A deep learning framework for burn injury assessment and TBSA estimation.medRxiv · 2026
- Artificial intelligence for outcome prediction in burn care: A scoping reviewBurns · 2026
- Large Language Models in Critical Care Medicine: Scoping ReviewJMIR Medical Informatics · 2025
- Medical Record Abstraction for Quality Improvement in Sepsis Care Using Artificial IntelligenceJAMA Network Open · 2026
- Augmenting large language models with clinical knowledge graph for personalized perioperative fluid therapy question answeringPLOS Digital Health · 2026
- Evaluating outcomes that matter: development of a multi-criteria decision analysis framework in specialized burn careBMC Health Services Research · 2026