Engineering of pH-regenerable anti-insulin single chain variable fragments (scFvs) for continuous insulin monitoring.
Qianming Xu, Ellie D Wilson, Mai Hamasaki, Hirobumi Suzuki, Ayumi Tanaka, Junko Okuda-Shimazaki, Miho Oda, Daimei Miura,
Department of Biotechnology and Life Science, Graduate School of Engineering, Tokyo University of Agriculture and Technology, 2-24-16 Naka-cho, Koganei, Tokyo 184-8588, Japan. · Lampe Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill, North Carolina State University, North Carolina State University, Chapel Hill, NC, 27599, USA.
Key points
From the paper's conclusion- To our knowledge, this is the first report of an anti-insulin antibody capable of binding site regeneration at pH 6.0, representing an important step toward antibody-based continuous insulin monitoring and continuous sensing of protein biomarkers.
Abstract
To realize the continuous monitoring of insulin, the development of a regenerable engineered antibody is expected, whose binding constant is modulated by the mild in situ stimulation for future in vivo application. In this study, we aimed to develop pH-responsive anti-insulin antibodies based on a clinically established analytical antibody, the HUI-018 anti-insulin antibody. Its high-resolution co-crystal structure with human insulin (PDB ID: 6Z7W) provides a uniquely precise blueprint for molecular engineering by preparing engineered HUI-018 single-chain variable fragment (scFv). Among the engineered variants, the N93H/E101K mutant exhibited the biggest pH-responsiveness, showing a 5.2-folds increased dissociation rate at pH 6.0 while maintaining binding affinity and specificity comparable to wild-type (WT) at pH 7.4. Repeated cycles of insulin binding at pH 7.4 and regeneration at pH 6.0 demonstrated that the N93H/E101K mutant achieved substantially higher regeneration and rebinding efficiencies than WT. These results demonstrate that engineered pH-responsive antibody enables efficient binding site regeneration through mild pH change. To our knowledge, this is the first report of an anti-insulin antibody capable of binding site regeneration at pH 6.0, representing an important step toward antibody-based continuous insulin monitoring and continuous sensing of protein biomarkers.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Reagent-Free Molecular Pendulum Biosensor with Antibody–Aptamer Dual Recognition for Protein AnalysisACS Sensors · 2026
- Rational Design of pH-Responsive Split Aptamer Probes for Controllable Ligand Binding.ACS chemical biology · 2026
- A functional investigation of antibody Fc-FcRn variant binding guided by in silico free energy perturbation methods.Journal of molecular biology · 2026
- The Long and Lucky Road to Continuous Molecular Monitoring: A Personal History of Electrochemical Aptamer-Based Sensors.Accounts of chemical research · 2026
- Enzyme-linked immunosorbent assay-based screening approach for phage-independent affinity maturation of single-domain antibodies.Journal of bioscience and bioengineering · 2026
- Beyond metabolites: A wearable biointerface integrating antibody and aptamer probes for the real-time tracking of proteins in vivo.Science advances · 2026