Rapid comparative evaluation of 2 ambient artificial intelligence applications in a learning health system.
David A Dorr, Timothy Joslin, Emma Young, Anthony Cheng, Amrish Pipalia, Vishnu Mohan, Jeffrey A Gold
Division of Informatics, Clinical Epidemiology, and Translational Data Science, OHSU, Portland, OR 97239, United States. · Department of Family Medicine, OHSU, Portland, OR 97239, United States.
Key points
From the paper's conclusion- Rapid, multidimensional evaluation within a LHS can assess AAS across domains of implementation, efficiency, clinician experience, and documentation quality and safety. Ongoing monitoring of efficiency, documentation quality, and use patterns is essential.
Abstract
OBJECTIVE: To evaluate ambient Artificial Intelligence (AI) scribe systems (AAS) across multiple domains using a rapid learning health system (LHS) approach, including provider satisfaction, efficiency, documentation quality, usability, and patient sentiment. MATERIALS AND METHODS: This LHS evaluation compared 2 AAS systems (Abridge and Nabla) among 100 providers over 90 days. Evaluation incorporated a cluster randomized crossover comparison, analysis of use and EHR-based workflow outcomes, and standardized simulated encounters to assess documentation quality and safety. Outcomes included provider satisfaction, efficiency, note quality, usability, and patient sentiment. RESULTS: In standardized simulated encounters, both systems achieved 76% note element accuracy with minimal risk for harm. In the randomized crossover comparison, Abridge demonstrated higher usability scores (78.5 vs 73) and was preferred 3:1 over Nabla, which had higher automated speech recognition error rates. Across 16 479 clinical encounters, AAS was used in 35.7% of visits. Total EHR time decreased by approximately 5 minutes per day; same-day chart closure increased by approximately 5% during the initial crossover period, but this effect was attenuated. Provider experience was positive (Net Promoter Score [NPS] 53). DISCUSSION: Both systems demonstrated comparable documentation accuracy and modest efficiency gains while improving clinician satisfaction. Despite similar performance, clinicians reported differences in usability and preference. Adoption below 40% reflected the trade-off between documentation support and verification burden. CONCLUSION: Rapid, multidimensional evaluation within a LHS can assess AAS across domains of implementation, efficiency, clinician experience, and documentation quality and safety. Ongoing monitoring of efficiency, documentation quality, and use patterns is essential.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Randomized Trial Protocol: Head-to-Head Comparison of Two Ambient Artificial Intelligence Documentation Tools on Clinician UsabilitymedRxiv · 2026
- Crossover Evaluation of Two Ambient AI Scribe Tools in the Emergency DepartmentApplied Clinical Informatics · 2026
- Beyond Time Saved: A Framework for Comprehensive Evaluation of AI Clinical Documentation.JMIR medical informatics · 2026
- Evaluating ambient artificial intelligence documentation: effects on work efficiency, documentation burden, and patient-centered careJournal of the American Medical Informatics Association · 2025
- Ninety-Six Ways to Measure a Scribe: Fragmented Evaluation of Ambient Scribes in HealthcarearXiv · 2026
- The Effect of Ambient Artificial Intelligence Documentation on Clinician Workload, Efficiency, and Patient Experience in a Multisite Emergency Department Network.Applied clinical informatics · 2026