Journal of the American Medical Informatics Association : JAMIA

Small language models in clinical medicine: a systematic review of performance, safety, and deployment feasibility.

Alon Gorenshtein, Mahmud Omar, Yiftach Barash, Jonathan B Kruskal, Muneeb Ahmed, Olga R Brook, Ben Illigens, Girish N Nadkarni,

BRIDGE GenAI Lab, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA 02215, United States. · Department of Radiology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA 02215, United States.

Review

Key points

From the paper's conclusion
  • Routine reporting of calibration and uncertainty and measurement of end-to-end clinical performance are prerequisites for responsible SLM deployment.

Abstract

OBJECTIVES: To review the clinical evidence for small language models (SLMs), 4 billion parameters or fewer, for performance, safety, and deployment feasibility. MATERIALS AND METHODS: We searched 5 databases through February 10, 2026 for English-language reports of an SLM on a clinical task, following PRISMA 2020 under a PROSPERO-registered protocol. Two reviewers independently assessed eligibility (Cohen κ = 0.93) and rated methodological quality and transparency. We calculated a relative task score (RTS): the primary metric of each study's best-performing qualifying SLM, divided by a study-specific reference comparator selected by a uniform hierarchy, calculated by the review authors. RESULTS: Eleven studies (7 peer-reviewed, 4 preprint or technical-report) were eligible. Across the 9 studies with a ratio-scale reference comparator, RTS ranged from 0.30 to 2.36; 1 was a raw difference on a non-ratio scale and 1 had no comparator. We did not pool estimates, given heterogeneity. Hallucination was evaluated in 6 of 11 studies, a scalar calibration-error metric or epistemic uncertainty in 0 of 11 (1 reported a calibration curve only), and on-hardware inference timing in 2 of 11. Our memory model estimated that a 4-billion-parameter model requires about 9.3 GB at a 2048-token context, indicating single-GPU memory feasibility rather than demonstrated deployment. DISCUSSION: Domain-adapted SLMs are memory-feasible, but the evidence base is too small and heterogeneous for inferential comparison with larger models, and safety properties (including adversarial robustness) go unmeasured. CONCLUSION: Routine reporting of calibration and uncertainty and measurement of end-to-end clinical performance are prerequisites for responsible SLM deployment. PROSPERO REGISTRATION: CRD420261331444.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers