MADE: leveraging informative missingness and temporal evaluation for electronic health record-based deterioration prediction in general wards.
Yechan Mun, Jee Hwan Ahn, Chang Youl Lee, Byungeun Ahn, Jin Won Huh, Kyung Soo Chung
Research Department, AITRICS. Inc, Seoul 06627, Republic of Korea. · Department of Pulmonary and Critical Care Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul 05505, Republic of Korea.
Key points
From the paper's conclusion- MADE supports scalable observation-aligned risk monitoring, particularly for MAE, while sepsis prediction may require site-specific recalibration or feature-set adaptation under cross-institution domain shifts.
Abstract
OBJECTIVE: Electronic health record (EHR) time series are irregularly sampled and frequently incomplete, with missingness potentially carrying clinically informative signals. We developed Masked-Attention-based timestamp-wise Data Embedding (MADE), a missingness-aware model for continuous prediction of deterioration in general wards, and evaluated it across heterogeneous hospitals. MATERIALS AND METHODS: Observed variables were tokenized into feature-specific embeddings and processed by a masked-attention Transformer, followed by bi-LSTM temporal aggregation for risk prediction. MADE was evaluated for major adverse event (MAE) and sepsis in 1 internal (SVH) and 2 external cohorts (AMC, HUMC) against conventional and deep learning baselines. Ablation studies compared no imputation with last observation carried forward (LOCF) and multiple imputations by chained equations (MICE). Discriminative performance was assessed using the area under the receiver operating characteristic curve (AUROC) and precision-recall curve (AUPRC). Clinical utility and reliability were assessed using decision curve analysis, Brier score, and expected calibration error (ECE). RESULTS: MADE achieved strong discrimination for MAE (AUROC 0.966/0.902/0.825 for SVH/AMC/HUMC) and sepsis (AUROC 0.934/0.874/0.776). The no-imputation configuration generally outperformed LOCF and MICE, particularly for MAE and for sepsis AUPRC, supporting preservation of informative missingness. Decision curves showed favorable net benefit for MAE and competitive benefit for sepsis. Calibration indicated modest underestimation at higher risks, suggesting site-specific recalibration. DISCUSSION: MADE mitigates limitations of fixed grid and imputation-dependent EHR modeling by jointly leveraging observed values and missingness patterns under heterogeneous sampling. CONCLUSION: MADE supports scalable observation-aligned risk monitoring, particularly for MAE, while sepsis prediction may require site-specific recalibration or feature-set adaptation under cross-institution domain shifts.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Missingness-Aware Prior-Data Fitted Network for Irregular Clinical Time-SeriesarXiv · 2026
- Development and validation of a clinical wearable deep learning based continuous inhospital deterioration prediction modelNature Communications · 2025
- Retrieval-Augmented Multimodal Language Model with Heterogeneous Evidence Integration for Clinical PrognosisarXiv · 2026
- Multimodal transformer decoder for the early detection of clinical deterioration in heart failure: Insights from temporal lead-time analysisEuropean Heart Journal · 2026
- Feature-token clinical transformer for 24-h landmark mortality risk stratification in critically ill patients with heart failure: development and multicenter external validation.Frontiers in cardiovascular medicine · 2026
- Adaptive Temporal Latent Architecture using Structured Electronic Health Records: A Temporal Physiologic-State Centric Foundation Model.Research square · 2026