Analytical Evaluation of Urinary CXCL10 as a Biomarker for Kidney Allograft Rejection.
Manoela de Paula Ferreira, Elsa Ho, Tom Blydt-Hansen, Li Wang
The Canadian Donation and Transplantation Research Program, Edmonton, AB, Canada. · Department of Pathology and Laboratory Medicine, University of British Columbia, Vancouver, BC, Canada.
Key points
From the paper's conclusion- Urinary CXCL10 exhibits robust reproducibility and can be handled the same way as other clinical urine analytes, indicating it is suitable as a diagnostic biomarker to assess patients after kidney transplant.
Abstract
BACKGROUND: Urinary C-X-C motif chemokine ligand 10 (CXCL10), a chemokine for leukocyte recruitment, is a sensitive and specific biomarker for diagnosing kidney transplant rejection. We performed comprehensive test validations for CXCL10 using urine samples with the Meso Quickplex SQ 120, following CLSI guidelines. METHODS: Precision, linearity, recovery, freeze-thaw cycles, interference from hemoglobin, triglyceride, conjugated bilirubin, and protein, as well as lot-to-lot variation were assessed. Fresh urine samples were held at room temperature (RT) for 1, 2, 4 h or at 4°C for 1, 2, 4, 24 h before processing, then centrifuged at different speeds (400, 800, 1500, and 2000g) and for different time periods (6, 10, and 20 min) at the same temperature. RESULTS: Within-run and between-run precision were <7% and <15% for both QC and human urine, with the latter being slightly larger. Linearity was up to 900 ng/L with a limit of quantitation of 2.45 ng/L. The recovery for urinary CXCL10 ranged from 94% to 102%. CXCL10 was stable for up to 6 freeze-thaw cycles. No interferences were detected with proteinuria and bilirubinuria. Lipuria and severe hematuria (hemoglobin, Hb = 5 g/L) were found to interfere with CXCL10 measurements. CXCL10 is stable in unprocessed urine stored at RT for 4 h and at 4°C for 24 h. Various centrifugation time and speeds had insignificant effects on CXCL10 measurement. CONCLUSIONS: Urinary CXCL10 exhibits robust reproducibility and can be handled the same way as other clinical urine analytes, indicating it is suitable as a diagnostic biomarker to assess patients after kidney transplant.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Urinary CXCL10 for detection of rejection and infection at 1-year posttransplant.Transplant international : official journal of the European Society for Organ Transplantation · 2026
- Validation of the TransplantTrace cfDNA Kidney assay for measurement of donor-derived cell-free DNA in transplant recipients.Frontiers in medicine · 2026
- Longitudinal Urinary C-X-C Motif Chemokine Ligand 9: Inflammatory Trajectory Phenotypes and Contemporaneous Association With Graft Injury After Kidney Transplantation.Transplantation · 2026
- Proteomics-based immune activation signatures are associated with kidney allograft rejection.Frontiers in medicine · 2026
- To TTV or Not to TTV? A Combined Urinary Biomarker Approach in Kidney Transplant Recipients Using Torque Teno Virus, Cell-Free DNA, and BK Polyomavirus MeasurementsmedRxiv · 2026
- Urinary CXCL-9 outperforms TNF-α for non-invasive diagnosis of immune checkpoint inhibitor–associated acute interstitial nephritisNephrology Dialysis Transplantation · 2026