Preparation of B. Braun Easypump® II elastomeric devices with Chemfort™ closed system transfer devices (CSTDs) in uncontrolled environments.

Louisa Knowles, Abi Jenkins

Pharmacy Department, University Hospitals Birmingham NHS Foundation Trust, Birmingham, UK.

Key points

From the paper's conclusion
  • Preparation using Chemfort™ CSTDs was associated with reduced microbial contamination and shorter preparation times compared with needle-based methods. CSTDs may provide a useful risk-reduction strategy for nurse-prepared elastomeric infusions in OPAT services, although further evaluation in larger studies is required.

Abstract

BACKGROUND: Outpatient parenteral antimicrobial therapy (OPAT) enables patients to receive intravenous antimicrobials outside hospital settings. Elastomeric infusion devices facilitate continuous antibiotic delivery; however, limited stability data and constrained aseptic unit capacity have led some services to adopt nurse-led 'fresh-fill' preparation in uncontrolled environments, which may increase microbial contamination risk. OBJECTIVES: To evaluate whether preparation of B. Braun Easypump® II elastomeric devices using Chemfort™ closed system transfer devices (CSTDs) in uncontrolled environments reduces microbial contamination compared with preparation using needles and syringes. METHODS: Forty-six elastomeric devices were prepared with tryptic soy broth by eight operators across three uncontrolled rooms using either Chemfort™ CSTDs (n = 23) or needles and syringes (n = 23). Aseptic non-touch technique was followed. Devices were incubated at 32°C for 7 days before microbiological testing. Environmental monitoring included settle plates and finger dabs. Fisher's exact test was used to analyse contamination rates. RESULTS: No contamination occurred in devices prepared using CSTDs (0/23), whereas 5/23 (22%) prepared using needles were contaminated. This difference was statistically significant (P = 0.0491). Preparation times were shorter and more consistent using CSTDs (median 26 min; range 20-40) compared with needles and syringes (median 34 min; range 22-64). CONCLUSIONS: Preparation using Chemfort™ CSTDs was associated with reduced microbial contamination and shorter preparation times compared with needle-based methods. CSTDs may provide a useful risk-reduction strategy for nurse-prepared elastomeric infusions in OPAT services, although further evaluation in larger studies is required.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Preparation of B. Braun Easypump® II elastomeric devices with Chemfort™ closed system transfer devices (CSTDs) in uncontrolled environments — Science Skim