Systemwide Quality Improvement Strategy to Reduce Nitrous Oxide Environmental Emissions in a Brazilian Health Network.
Leopoldo Muniz da Silva, Helidea de Oliveira Lima, Ana Cláudia Fernandes Araújo, Rafael Souza Fava Nersessian, Saullo Queiroz Silveira, Fernando Nardy Bellicieri, Leandro Reis Tavares, Rodrigo Gavina da Cruz,
Rede D'Or, D'Or Institute for Research and Education (IDOR), Rio de Janeiro, RJ, Brazil. · Postgraduate Program in Anesthesiology, Surgical Sciences, and Perioperative Medicine, Department of Surgery, Faculdade de Medicina FMUSP, Universidade de São Paulo, São Paulo, SP, Brazil.
Key points
From the paper's conclusion- A systemwide QI strategy was associated with an 89.6% reduction in N₂O-attributable CO₂e emissions across 54 hospitals, demonstrating that N₂O reduction can be incorporated into routine perioperative governance.
Abstract
BACKGROUND: Nitrous oxide (N₂O) is a potent greenhouse gas commonly used in perioperative care and with substantial environmental impact. This study evaluated a systemwide quality improvement (QI) initiative designed to achieve 85% reduction in carbon dioxide equivalent (CO₂e) emissions attributable to N₂O across a large private Brazilian hospital network. METHODS: A multicenter before-after QI protocol was implemented across 54 hospitals between September/2024 and December/2025 using sequential Plan-Do-Study-Act cycles: cycle 1 delivered a systemwide educational program; cycle 2 introduced operational restriction of N₂O through disconnection of anesthesia workstations from the central pipeline with protocol-guided use limited to pediatric inhalational anesthesia induction; and cycle 3 implemented hospital-level benchmarking with structured feedback and leadership engagement. RESULTS: Baseline mean N₂O consumption per surgical procedure was 0.7 ± 0.9 kg, with total network consumption of 15,954 kg/month. Hospital operational age was not associated with baseline consumption intensity (β = 0.008; 95% CI - 0.001 to 0.02; p = 0.11). At the network level, baseline N₂O-related CO₂e emissions showed a median of 4.23 kt (IQR 4.11-4.67). Following implementation, median monthly emissions decreased to 0.29 kt (IQR 0.24-0.66). Mean monthly emissions decreased from 4.36 to 0.45 kt, an estimated absolute reduction of 3.90 kt (95% CI 3.60-4.21) and a relative reduction of 89.6%. No adverse events related to N₂O restriction were reported through the institutional incident reporting system. CONCLUSION: A systemwide QI strategy was associated with an 89.6% reduction in N₂O-attributable CO₂e emissions across 54 hospitals, demonstrating that N₂O reduction can be incorporated into routine perioperative governance.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- System-Level Reduction in Anesthetic Greenhouse Gas Emissions: Central Nitrous Oxide Deactivation, Clinical Decision Support, and Secular Change in a Multicenter Interrupted Time-Series Study.Anesthesia and analgesia · 2026
- Project SPRUCE: Formation of an International Consortium of Pediatric Anesthesia Groups to Reduce Greenhouse Gas Emissions from Inhaled Anesthetics.Anesthesiology · 2026
- Harnessing the Power of Education for a Low-carbon Future in Anaesthesia: A Narrative Review.Turkish journal of anaesthesiology and reanimation · 2026
- Greener Surgery, Greener Hospital: Organizational Strategies for Carbon Footprint Reduction in Anesthesia and Perioperative Departments.Cureus · 2026
- Implementation of green nursing practices in perioperative care: impact on safety, efficiency, and sustainability.Frontiers in public health · 2026
- Interventions to reduce desflurane use in hospitals: A systematic review.Anaesthesia and intensive care · 2026