Comprehensive hemodynamic assessment of the Fontan pathway using four-dimensional flow magnetic resonance imaging.
Muneaki Matsubara, Thibault Schaeffer, Jonas Palm, Teresa Lemmen, Christina Ruda, Heiko Stern, Nerejda Shehu, Shohei Miyazaki,
Department of Congenital and Pediatric Heart Surgery, TUM University Hospital, German Heart Center, Munich, Germany. · Department of Congenital Heart Disease and Pediatric Cardiology, TUM University Hospital, German Heart Center, Munich 80636, Germany.
Key points
From the paper's conclusion- Four-dimensional flow magnetic resonance imaging with iTFlow software enables comprehensive hemodynamic assessment throughout the Fontan pathway, revealing substantial patient-specific heterogeneity in energy efficiency. With larger cohorts and correlation with clinical outcomes, this technique may become a valuable screening tool for post-Fontan evaluation and long-term surveillance.
Abstract
OBJECTIVES: Conventional hemodynamic assessment of Fontan circulation relies on limited quantitative measurements. We evaluated the feasibility and clinical value of comprehensive flow visualization using four-dimensional flow magnetic resonance imaging to characterize patient-specific hemodynamic patterns in extracardiac total cavopulmonary connection. METHODS: Eight patients with extracardiac total cavopulmonary connection underwent four-dimensional flow magnetic resonance imaging at a median of 13.7 years postoperatively (interquartile range: 9.0-16.4 years). The Fontan pathway was segmented into five regions: extracardiac conduit, superior vena cava, central confluence, left pulmonary artery, and right pulmonary artery. Energy loss, maximum velocity, and kinetic energy were quantified for each segment using iTFlow software. Clinical outcomes were assessed during follow-up. RESULTS: Median age at total cavopulmonary connection was 1.8 years (interquartile range: 1.5-3.5), with 18 mm conduits in seven patients and 22 mm conduit in one patient. During a median follow-up of 17.3 years, two patients underwent re-operation after magnetic resonance imaging evaluation (tricuspid valve replacement and ascending aortic reconstruction); all remained alive without Fontan failure. Energy loss differed significantly across segments (p = 0.011), being highest in the conduit and central confluence, with remarkable inter-patient variability superimposed (conduit values varying 35-fold from 0.025 to 0.887 mW). Maximum velocity strongly correlated with energy loss (r = 0.92, p = 0.001), suggesting velocity may serve as an accessible surrogate. Atrioventricular valve regurgitation severity did not consistently correlate with energy loss. CONCLUSIONS: Four-dimensional flow magnetic resonance imaging with iTFlow software enables comprehensive hemodynamic assessment throughout the Fontan pathway, revealing substantial patient-specific heterogeneity in energy efficiency. With larger cohorts and correlation with clinical outcomes, this technique may become a valuable screening tool for post-Fontan evaluation and long-term surveillance.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Junctional Rhythm Associated With Multilevel Flow Reversal in a Well-Functioning Fontan Detected by 4-Dimensional Flow.JACC. Case reports · 2026
- Cardiovascular magnetic resonance-derived hemodynamics predict adverse outcomes after Fontan palliation.Frontiers in cardiovascular medicine · 2026
- Comprehensive Evaluation of Fontan-Associated Liver Disease: The Role of Magnetic Resonance Imaging.Diagnostics (Basel, Switzerland) · 2026
- Left Ventricular Diastolic Intraventricular Pressure Differences and Propagation Velocity with 4D-Flow MRI in Patients with Hypertrophic CardiomyopathymedRxiv · 2026
- 4D-Flow MRI Assessment of Ascending Aortic Energy Loss in Quadricuspid Aortic Valve.JACC. Case reports · 2026
- The Lymphatic System in the Fontan Circulation: Pathophysiology, Imaging and Therapeutic Interventions.Pediatric cardiology · 2026