Geophysical Journal International

When does array moveout help borehole phase picking?

Isao Kurosawa

Computational

Key points

From the paper's conclusion
  • We therefore recommend the per-trace picker as the safer default.

Abstract

Deep-learning phase pickers are increasingly deployed on borehole microseismic arrays. Two questions central to operational monitoring nevertheless remain poorly quantified. The first is how well such models generalize to a site they were not trained on. The second is whether the across-station moveout that an array provides actually improves that generalization. We address both with the AMBER benchmark (AI-Ready Downhole Microseismic Benchmark) of eight three-component downhole arrays. A waveform-direct picker that needs no velocity model is trained under a leave-one-site-out (LOSO) protocol. The other sites supply the training data; the held-out site is then evaluated zero-shot, with no fine-tuning. The contribution of cross-station moveout is tested in a controlled experiment. The identical two-dimensional U-Net is trained in two configurations that share the same data and training schedule. In the array configuration the station axis is convolved and moveout is available. In the per-trace configuration the input is a single station and moveout is removed. Collapsing the station axis also changes the receptive field, the normalization statistics and the composition of each mini-batch. Across the eight held-out sites the two configurations are level in median F1-mean (0.885 versus 0.878). Across sites the paired differences show no systematic advantage of the array configuration (Wilcoxon signed-rank p = 0.74). The array-minus-per-trace difference is instead strongly site-dependent and, at one site, catastrophically negative. At forge_19, only 0.45 per cent of the audited training earthquakes reach the site’s median P moveout of 70 ms. There the array P detector collapses (F1 0.18), while the per-trace model reaches a P F1 of 0.76. Score diagnostics and a full threshold sweep show a detection failure that no threshold choice repairs, rather than a timing error. A station-shuffle control suggests that, at forge_19, the array model uses relationships between stations beyond ordered moveout. The control does not by itself explain the collapse. Unattended monitoring is governed by worst-case rather than average performance. We therefore recommend the per-trace picker as the safer default. The array configuration is treated as a conditional, in-distribution enhancement. It should be used only after checking that the new site’s moveout is represented in the training data. The check screens only the upper tail of moveout and would not flag a site whose moveout is too small.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers