Feasibility of measuring walking speed in a diabetes clinic in primary care.
Richard Baskerville, Fiona Reid, Joanna Dawes, Patrick Esser, Pippa Oakeshott
Faculty of Health, Science and Technology, Oxford Brookes University, Oxford OX3 0BP, United Kingdom. · Faculty of Life Sciences and Medicine, King's College London, London WC2R 2LS, United Kingdom.
Key points
From the paper's conclusion- Timed walk was the most feasible and acceptable to patients and staff. Results were similar on average to accelerometry and treadmill.
Abstract
BACKGROUND: Usual walking speed may predict cardiovascular disease in type 2 diabetes, but it is not routinely assessed in UK primary care. OBJECTIVE: To examine the feasibility of three methods of assessing walking speed in patients with diabetes in general practice: timed walking, accelerometry, and treadmill walking. METHODS: We approached consecutive mobile patients attending a general practice diabetes clinic. Consenting participants performed a timed 28-m walk (4 × 7 m) at their usual pace in the surgery corridor while wearing an accelerometer, followed by a 3-minute treadmill walk. Measures were repeated after 6 months. Differences in walking speeds between methods and between timepoints were assessed by Bland-Altman limits of agreement. RESULTS: Recruitment rate was 91% (30/33). Mean age of participants was 59.6 years (range 37-75), mean body mass index was 30.6 kg/m2 (21.0-46.4), and 17% had a history of cardiovascular disease. Average duration of diabetes was 10 years (range 1-40). Twenty-five participants (83%) repeated assessments at 6-month follow-up.Average (SD) walking speed on the timed walk was similar to both accelerometer and treadmill: 1.12 (0.13), 1.15 (0.16), and 1.01 (0.39) m/s, respectively. Bland-Altman analysis showed good agreement for repeat tests and, on average, between methods. Limits of agreement between timed walk and treadmill were wide. Feedback from seven participants and three practice staff indicated acceptability of all tests, but treadmill testing took longer and least feasible. CONCLUSIONS: Timed walk was the most feasible and acceptable to patients and staff. Results were similar on average to accelerometry and treadmill.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Concurrent validity and TEST-RETEST reliability of the incremental shuttle walk TEST in patients with type 2 diabetes mellitus.Physiotherapy theory and practice · 2026
- Gait characteristics in older adults using the ProtoKinetics Zeno walkway: the atherosclerosis risk in communities (ARIC) study.Frontiers in aging neuroscience · 2026
- Not all steps are equal: independent prospective associations of stepping volume and patterns with incident type 2 diabetes mellitus in the Maastricht studyInternational Journal of Behavioral Nutrition and Physical Activity · 2025
- Average Acceleration as a Measure of Physical Activity Across Sensor Locations in Participants With Heart Failure or Chronic Obstructive Pulmonary Disease and Healthy Volunteers: Secondary Analysis.JMIR biomedical engineering · 2026
- How Many Trials Are Needed for Consistent Clinical Gait Assessment?Applied Sciences · 2025
- TUG-Defined Mobility Impairment and Physical Performance in Adults with Type 2 Diabetes Mellitus.Journal of clinical medicine · 2026