Multicountry evaluation of indoor air in homes and schools: results from K-HEALTHinAIR project
O Boghenco, MO Corda, A Gómez-López, R González-Colom, A Badyda, A Kristian, S De Leede, A Van Grieken,
Key points
From the paper's conclusion- Key messages • Indoor activities and heating types strongly affect IAQ, with frequent PM2.5 guideline exceedances in smoking, wood-heated, and poorly ventilated homes. • CO2 and PM levels often exceed guidelines in schools and homes, especially during winter, varying widely between countries and indicating potential health risks.
Abstract
Background People spend 80 to 90% of their time indoors, making indoor air quality (IAQ) a major public health factor. Poor IAQ can increase the risk of respiratory issues, heart disease, cognitive impairments, and cancer. This study, within K-HEALTHinAIR project, aims to evaluate potential exposure risks in homes and schools, across four countries. Methods Data were collected using low-cost sensors to monitor CO₂, PM10, and PM₂.₅. Annual 24-hour average pollutant levels for 2025 were calculated, along with a risk analysis based on the frequency of exceedance of the guideline. Results CO₂ levels in homes generally stay below guidelines, with slight winter increases, particularly in wood-heated homes (up to 893 ppm), while schools showed exceedance during winter in Poland (954 ppm). Elevated PM2.5 concentration occurs in homes with district heating in the Netherlands (19.4 μg/m³), and air conditioning (34.8 μg/m3), smoking (93.9 μg/m³), and gas cooking (29.5 μg/m³) in Spain. In schools PM₂.₅ levels are higher in Polish schools (22.0 μg/m³) compared to those in Austria (9.5 μg/m³). Risk analysis indicates that CO₂ exceedance was 2 % (Spain), 8% (Austria), 11 % (the Netherlands), and 19 % (Poland), with wood-heated homes showing the highest frequencies. PM₂.₅ presents the highest exceedance rates: 36 % in Spanish smokers’ homes, 30 % in Dutch homes with passive smokers, 56 % in Austrian wood-heated homes, and 24 % in Polish homes heated by electricity. In schools, CO₂ exceedances reach 41 % in Austria and 34 % in Poland, while PM₂.₅ exceeds limits in 24 % of Polish schools compared to 10 % in Austria. Conclusions The findings highlight the important influence of indoor activities and household characteristics on IAQ and the potential health risks. Acknowledgements: This study has been performed in the framework of the K-HEALTHinAIR project funded by the European Union (Grant agreement ID: 101057693). Key messages • Indoor activities and heating types strongly affect IAQ, with frequent PM2.5 guideline exceedances in smoking, wood-heated, and poorly ventilated homes. • CO2 and PM levels often exceed guidelines in schools and homes, especially during winter, varying widely between countries and indicating potential health risks.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Dual burden of PM and airborne viruses in primary schools: A pilot study in Patras, GreeceEuropean Journal of Public Health · 2026
- Integrated Evidence of Winter Childhood Exposure to CO2 in Housing and Classrooms in Santiago de ChileBuildings · 2026
- Indoor Air Quality in Critical Indoor Environments: A Review PaperWater Air & Soil Pollution · 2025
- Indoor air quality in preschools in the Republic of Srpska, Bosnia and Herzegovina: a pilot studyEuropean Journal of Public Health · 2026
- Polycyclic aromatic hydrocarbon (PAH) levels in indoor air and their associated health risks for children across Europe.Environmental research · 2026
- Assessing the role of ventilation and indoor air quality in SARS-CoV-2 transmission risk in Belgian nursing homes: the AIR-CO study.Archives of public health = Archives belges de sante publique · 2026