Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology

Incident heart failure in patients with screening-detected atrial fibrillation: a post hoc analysis of the STROKESTOP and STROKESTOP II studies.

Gina Sado, Carl Bonander, Katrin Kemp Gudmundsdottir, Catarina Djupsjö, Viveka Frykman, Johan Engdahl, Emma Svennberg

Karolinska Institutet, Department of Medicine, Karolinska University Hospital Huddinge, Sweden. · School of Public Health and Community Medicine, Institute of Medicine, University of Gothenburg.

Key points

From the paper's conclusion
  • Screening-detected atrial fibrillation is associated with a high risk of heart failure, comparable to known atrial fibrillation, and is not a benign condition.

Abstract

BACKGROUND AND AIM: Atrial fibrillation is associated with increased risks of stroke, heart failure, and death. While stroke prevention is a key focus, heart failure is more frequent and a major contributor to mortality in atrial fibrillation. This study aimed to assess the incidence and timing of heart failure in screening-detected atrial fibrillation. METHODS: This post hoc analysis included participants without prior heart failure from the STROKESTOP and STROKESTOP II randomized screening studies, in which individuals aged 75-76 years were invited to ECG-based atrial fibrillation screening. Incident heart failure diagnoses were obtained from national registries. Incidence rates were calculated per 100 person-years, and Cox regression was used to estimate hazard ratios (HRs). RESULTS: In STROKESTOP, 23% of participants with screening-detected atrial fibrillation developed heart failure (3.76 per 100 person-years), compared with 4.43 in patients with known atrial fibrillation and 1.08 in patients without atrial fibrillation. Screening-detected atrial fibrillation was associated with a threefold higher heart failure risk vs. no atrial fibrillation (adjusted HR 3.19) and a risk comparable to known atrial fibrillation (adjusted HR 2.86). In STROKESTOP II, 20% developed heart failure (4.19 per 100 person-years), compared with 3.52 in known atrial fibrillation and 0.93 without atrial fibrillation. Screening-detected atrial fibrillation was associated with a fourfold higher heart failure risk vs. no atrial fibrillation (adjusted HR 4.73) and a higher risk than known atrial fibrillation (adjusted HR 2.59). CONCLUSION: Screening-detected atrial fibrillation is associated with a high risk of heart failure, comparable to known atrial fibrillation, and is not a benign condition.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers