Impact of saline irrigation on haemolysis, silent cerebral lesion incidence, thermal dynamics, and bubble formation in pulsed field ablation with a variable-loop circular catheter
Dongtao Zhou, Mengmeng Li, Zhigang Song, Chenxi Jiang, Wei Wang, Ribo Tang, X L Zhao, Changyi Li,
Beijing Anzhen Hospital
Key points
From the paper's conclusion- To comprehensively evaluate the effect of irrigation with the variable-loop circular catheter (VLCC), the following experiments were performed: (i) ex-vivo potato model: to evaluate the lesion depth, bubble formation, and thermal effects in different irrigation regimens; (ii) in vitro blood pool and cardiac ablation: to determine the haemolysis status and tissue temperature change after PFA; (iii)
Abstract
AIMS: Though pulsed-field ablation (PFA) has demonstrated an excellent safety profile in reducing collateral injury to the oesophagus and phrenic nerve, it is still associated with specific effects, including electrode heating, haemolysis, and electrolysis due to excessive energy dispersion. This study aims to assess whether saline irrigation during PFA application could mitigate these risks. METHODS AND RESULTS: To comprehensively evaluate the effect of irrigation with the variable-loop circular catheter (VLCC), the following experiments were performed: (i) ex-vivo potato model: to evaluate the lesion depth, bubble formation, and thermal effects in different irrigation regimens; (ii) in vitro blood pool and cardiac ablation: to determine the haemolysis status and tissue temperature change after PFA; (iii) in vivo swine ablation (n = 8), and (iv) clinical randomized trial (n = 25): to compare the efficacy and safety profile between low (4 mL/min) and high (30 mL/min) flow irrigation using the VLCC. Though peak core temperatures at 5 mm depth were all < 50°C under low- and high-irrigation, high irrigation significantly mitigated the instant electrode and deep tissue heating both in the potato and isolated cardiac models. Ex vivo potato slices showed that high-flow irrigation produced the deepest lesion sets when compared to low-flow irrigation (5.94 ± 0.29 mm vs. 5.36 ± 0.33 mm, P = 0.043). Assessment from a high-speed camera and bubble detector demonstrated that high-flow irrigation significantly reduced the total number of gaseous bubbles (54.50 IQR 53.00-56.75 vs. 82.00 IQR 72.00-83.00, P < 0.001) and eliminated the occurrence of larger bubbles. The high-flow irrigation group showed a smaller increase in the level of free haemoglobin immediately after the procedure across the blood pool, swine, and clinical models. Haptoglobin and lactate dehydrogenase levels were also attenuated by high irrigation in the in vivo swine model and clinical trial. One swine in the low-irrigation group developed an acute cerebral lesion (3 mm). The clinical trial confirmed that the incidence of silent cerebral lesions was significantly lower in the high-flow irrigation group (16.7% vs. 66.7%, P = 0.036). CONCLUSION: Proper saline irrigation during PFA with VLCC may mitigate electrode-associated haemolysis, reduce electrode and tissue temperature, limit bubble aggregation, and be associated with a lower incidence of silent cerebral lesions, the clinical significance of which remains unclear.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Assessment of temperature dynamics in pulsed field ablation with a variable-loop circular catheter: a comparative analysis of waveform configurations and irrigation rates in specimens of bovine ventricular myocardiumEP Europace · 2025
- Comparative assessment of the thermal footprints of pulse field ablation systemsEuropean Heart Journal · 2026
- Is the Esophagus Spared During Pulsed Field Ablation?Pacing and Clinical Electrophysiology · 2026
- Effect of Pulsed Field Timing Sequence and Electrode Cooling on Ablation Safety and Efficacy Surrogates: A Preclinical Study.Circulation. Arrhythmia and electrophysiology · 2026
- Radiofrequency ablation using cold saline irrigation allows safe prolonged energy delivery and creates deep lesionsEuropean Heart Journal · 2026
- Clinical Implications of Hemolysis after Pulsed Field Ablation - What Can We Learn from Benchtop Models and Preclinical Experiments.Heart rhythm · 2026